21
January 2020
|
Solar Stik
®
, Inc.
Operator and Maintenance Manual for PRO-Verter RMK LAN
2 A Fuse
3 V Coin
Cell Battery
3. Slide out the control board, noting which grooves in the interior of the housing are used. The coin
cell battery and fuse (see section III) are on the underside of the circuit board.
4. Remove the coin cell battery and test the voltage. A fully charged coin cell battery will provide
~3.2 VDC. If the voltage is 2.75 VDC or less, it is fully discharged; replace the battery and
proceed to step 10. If the voltage is higher than 2.75 VDC, reinstall the battery and proceed to
the next step.
Figure 25. Removing control board
Figure 26. Locations of coin cell battery and fuse on
control board
Figure 27. Removing coin cell battery
Figure 28. Testing coin cell battery voltages