August 2020
|
Solar Stik
®
, Inc.
50
|
24VDC PRO-Verter 7000-120 AGS Operator Manual
Cleaning the Air Filters
a. Squeeze the sides and
pull away to remove the
louvered vent cover..
b. The foam air filter sits on
top of the filter assembly.
c. Remove the foam filter.
Clean with water or
compressed air.
d. Reinstall the louvered cover in the proper orientation—leading edge of the baffles facing
toward the ground.
Note
: Only air intake
vents have air filters. The
exhaust vents do not. See
Figure 10 through Figure
12 for vent type locations.
Figure 19. Louvered vent cover
Figure 20. Air filter
Figure 21. Cover and filter removed
Figure 22. PRO-Verter air intake vent
Preventive Care and Maintenance
Note:
The function and efficiency of all electronic equipment is related to and dependent upon the
temperature at which it is operating. It performs optimally within a narrow temperature range and
less so as the temperature falls outside of that range.
Heat will cause the PRO-Verter to derate
.
Please use the following measures to mitigate against heat and other environmental effects:
• Shade the PRO-Verter from direct sun exposure and shelter it from the elements as much as
possible.
• Keep case lid and Inter-Connect covers closed to prevent water/dust intrusion
• Check the integrity of electrical connectors on a monthly basis.
• Turn off electrical appliances when they are not in use. This will save power and allow more
power to be available when it is needed.
• Clean the air filters of the PRO-Verter air intake vents monthly. Wash them with water, dry them
thoroughly, and place them back in the intake vents (see below). The filters must be cleaned
more frequently when high winds are frequent and particulate levels are high.
MAINTENANCE INSTRUCTIONS