Operating the Solar-Log 500 and 1000 via the Display
5.4.2 The meaning of the values in the overviews
The following table contains the values and their meaning in alphabetical order.
Name
Unit
Meaning
CO
2
to
The amount of carbon dioxide emissions
that have been avoided based on the power
output.
Y-current
kWh
The current yield for the selected period
Yield Current/
Target
%
The current value displays the ratio of the cur-
rent yield to the target yield for the selected
period.
Y-max
kWh
The maximum yield for the selected period.
Y-min
kWh
The minimum yield for the selected period.
Y-avg
kWh
The average output for the selected period.
Energy
kWh
The total output for the day
Y-target
kWh
The Solar-Log™ runs a forecasting statistics
function that specifies a certain target value
for each month. If the target value or higher
has been achieved, the forecasted output has
been produced.
Y-spec
Wh/Wp
The energy yield divided by the maximum
power. This value is a good reference value
when comparing plants.
Pac
Watt
Current amount of feed-in power P on the AC
side.
Pdc
Watt
Current amount of feed-in power P on the DC
side (Solargenerator) If only one multi-string
inverter has been selected, the individual
strings are displayed separately.
P-max
Watt
Maximum output for the day.
EF
%
The current efficiency from the generator
power and feed-in power. The manufacturer's
specification on the inverter's efficiency can
be checked here.