81
14. RESECTION MEASUREMENT
Only Z (height) of an instrument station is determined by the measurement.
• Known points must be measured by distance measurement only.
• Between 1 and 10 known points can be measured.
PROCEDURE
1. Select "Resection" in <Menu>.
2. Select "Elevation" to display <Resection/Known
point>.
3. Input the known point.
After setting the elevation and target height for the
first known point press
[NEXT]
to move to the
second point.
• Press
[PREV]
to return to settings for the
previous point.
When all required known points have been set,
press
[OK]
.
4. Sight the first known point and press
[MEAS]
to
begin measurement.
The measurement results are displayed on the
screen.
14.2 Height Resection Measurement