114
19. CHANGING THE SETTINGS
Select "Obs.condition" in <Configuration> and select "Atmos".
Items set and options (*: Factory setting)
Temperature
: -35 to 60°C (15*)/-22 to +140°F (59*) (When Dist.reso. is 1 mm)
Pressure
: 500 to 1400hPa (1013*)/375 to 1050mmHg (760*)/14.8 to 41.3
(inchHg) (29.9*) (When Dist.reso. is 1 mm)
Humidity input
: No (50%)*/Yes
Humidity
: 0 to 100 (%) (50*) (When Dist.reso. is 1 mm)
ppm (Atmospheric correction factor)
: -499 to 499 (0*) (When Dist.reso. is 1 mm)
•
[0ppm]
: Atmospheric correction factor returns to 0 and temperature and air pressure are set to the factory
settings.
• Atmospheric correction factor is calculated and set using the entered values of the temperature and air
pressure. Atmospheric correction factor can also be entered directly.
• The "Humidity" is displayed only when the "Humidity input" is set to "Yes".
• When 0.1 mm is selected in "Dist.reso", values can be input to the first decimal place.
• When the settings here are different between Basic mode and Program mode, Program mode settings are
prior for use.
19.4 Observation Conditions - Atmosphere