162
29.SELECTING/DELETING A JOB
Select the current JOB and Coordinate Search JOB.
• A total of 99 JOBs have been prepared, and JOB1 was selected when your iM was shipped from the factory.
• The names of the JOBs have been preset as JOB1 to JOB99; you can change them to any names you wish.
• Scale factor can be set for each JOB. Only scale factor of the current JOB can be edited.
Current JOB
Measurement results, instrument station data, known points data, notes and coordinate data are recorded
in the current JOB.
Registering known point data: "30.1 Registering/Deleting Known Point Data".
Coordinate Search JOB
The registered coordinate data in the JOB selected here can be read into coordinate measurement,
resection measurement, setting-out measurement, etc.
Scale correction
iM calculates horizontal distance and coordinates of a point using measured slope distance. If scale factor
has been set, scale correction is carried out during calculation.
Corrected horizontal distance (s) = Horizontal distance (S) × Scale factor (S.F.)
• When scale factor is set to “1.00000000”, the horizontal distance is not corrected.
Horizontal distance: "33.1 Observation Conditions - Angle/Tilt"
Observation Condition
Horizontal
distance (H Dist)
PROCEDURE JOB selection and scale factor setting
1. Select “JOB” in Data Mode.
2. Select “JOB selection”.
<JOB selection> is displayed.
3. Press
[LIST]
.
• JOB can also be selected by pressing
{
}
/
{
}
.
• The numbers to the right represent the number of data
items in each JOB.
• “*” means that the JOB has not been output to an external
device yet.
29.1 Selecting a JOB
Data
JOB
Known data
Code
JOB
JOB selection
JOB details
JOB deletion
Comms output
Comms setup
J O B s e l e c t i o n
J O B 1
L I S T
:
C o o r d s e a r c h J O B
: J O B 1