14. SETTING-OUT MEASUREMENT
78
To find a point where a target cannot be directly installed, perform REM setting-
out measurement.
PROCEDURE
1.
Install a target directly below or
directly above the point to be
found, then use a measuring tape
etc. to measure the target height
(height from the survey point to
the target).
2.
Press [S-O] in the OBS mode
screen to display <S-O>.
3.
Enter the instrument station data.
Station Data and Azimuth
Angle "
4.
Select “S-O data” and press
[DISP] until <S-O Ht.> is
displayed.
5.
Input height from the survey point
to the position to be set out in “SO
dist”.
6.
After inputting the data, press
[OK].
• The tilt screen is displayed if the
instrument is out of level.
Level the instrument.
14.3 REM Setting-out Measurement
3 . 3 0 0
m
H t .
H e i g h t :
1 . 0 0 0 m
H R
OK
DISP