8.5. Electronic Pressure Sensor (EPS)*
Electromagnetic field occurs due to movement
of pressurized membrane. The coil moves
vertically by nucleus due to electromagnetic
field. The water level is regulated according to
the frequency changes of the coil by electronic
card.
EPS
Testing component
1. Make sure there are no laundry in washing machine, tap is connected and opened, power cord is plugged. Put no
detergent in drawer.
2. Bring porgram knob to position 1 (Cotton 90°C program)
3. Press start button.
4. Wait for water intake step to finish. You can recognise it by listening the water sound or slightly opening and
observing detergent drawer.
5. As soon as water intake is over turn program knoc to position 0 (Off position)
6. Check water level from door glass. The water level should be just below door glass as seen in the picture below:
(There is a %10 tolerance with this level)
32013066