8.4. Valve
Valve is an electrical and mechanical component
which is designed to take water from network
system into the washing machine. It is operated by
PCB card.
Valves
Technical features
Nominal voltage
220-240 V
Frequency
50-60 Hz
Flow rate (washer valves)
7 L/min (±15 %)
Flow rate (dryer valve)
1.2 L/min (±15 %)
Operating water pressure
1-10 bar
Testing component
Check the resistance value on the component with multimeter as shown below. Washer valves’ water flow
rate should be 7 L/min ±15%. Dryer valve’s water flow rate should be 1.2 L/min ±15%. Washer valves’ coil
resistance values should be 3750Ω ±10%. Dryer valve’s coil resistance value should be 5190Ω ±10%.
Dryer Valve
Washer Valves