background image

2

CONTENTS

Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  3
Features  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  4
Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  5
Wiring  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  6
Installation Notes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  8
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  9
Model SWH-4000 Technical Specifications . . . . . . . . . . . . . . . . . . . . . .  10
FCC Digital Device Limitations  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  12
UL Standards Compliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  13
CE Marking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  14

Summary of Contents for SWH-4000

Page 1: ...1 Model SWH 4000 Multi Technology Mullion 125 KHz and 13 56 MHz Flex Reader Installation Guide Version A0 Part Number UM 104 September 2005...

Page 2: ...NTS Introduction 3 Features 4 Mounting 5 Wiring 6 Installation Notes 8 Troubleshooting 9 Model SWH 4000 Technical Specifications 10 FCC Digital Device Limitations 12 UL Standards Compliance 13 CE Mark...

Page 3: ...tors Refer to Table 1 for a complete list of compatible standards and data TABLE 1 Compatible Credential Formats Model SWH 4000 HID 26 Bit ISO 14443A MIFARE Sector HID Corporate 1000 ISO 14443B Serial...

Page 4: ...edentials badges disk tags and key fobs Reads both 125 kHz and 13 56 MHz credentials in the same reader Electrical protection reverse polarity diode protection on power lines Data lines high speed tra...

Page 5: ...5 MOUNTING Mount the reader module directly to a metal door frame or wall and snap the front cover in place as indicated in Figure 1 FIGURE 1 Mounting Assembly...

Page 6: ...er if not carefully mounted and tightly fastened in the connector body Table 3 indicates maximum wiring distances per Wiegand standard with the three most common gauges of cable TABLE 2 Connector Pins...

Page 7: ...ard is presented to the reader FIGURE 2 Beeper Wiring NOTE If you wire the beeper as shown in Figure 2 do not wire the beeper back to the controller Terminal Block 1 10 AC or DC RS 485 B RS 485 A Red...

Page 8: ...the controller to the reader The ground line of the local power supply must be connected to the power supply of the controller 3 The unit needs to be operated with a power source with limited power co...

Page 9: ...nd the green LED does not light when a qualified credential is presented Verify that the door strike and the green LED are wired correctly Verify that the access credential has been entered and that t...

Page 10: ...tially compliant credentials Other Standards Compliance deister SmartFrame in both 125 kHz and 13 56 MHz implementations HID Prox at 125 kHz All Formats Standard Color Black other colors available con...

Page 11: ...nd antenna structure of each individual credential Standard Wiegand Output including ID Pass Through Option Serial Number Read Fixed Wiegand bit stream option SmartFrame encrypted MIFARE Sector read a...

Page 12: ...l area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense This device complies with Part 15 of the FCC rules Operation is su...

Page 13: ...e bruits radioelectriques depassant les limites applicables aux appareils numeriques de la class A prescrites dans le Reglement sur le brouillage radioelectrique edicte par le ministere des Communicat...

Page 14: ...copy contact Software House and request the Declaration of Conformity document for Multi technology readers Software House 70 Westview Street Lexington MA 02421 U S A In case of alteration of the pro...

Page 15: ...15...

Page 16: ...sist in the installation testing operation and maintenance of the equipment described This document may not be reproduced in whole or in part without the written approval of Tyco International Copyrig...

Reviews: