ME 3000SP
User manual
Copyright © Shenzhen SOFARSOLAR Co., Ltd
- 26 -
4.
ME 3000SP should start to operate now.
You need to set the following parameters before ME 3000SP start to operate.
1)Set system time
8)*Set min discharge voltage
2)Set country
9)*Set max discharge current
3)Select battery type
10)*Set min protect voltage
4)*Set battery capacity
11)*Set discharge depth
5)*Set max charge voltage
12)*Set empty discharge voltage
6)*Set max charge current
13)*Set full charge voltage
7)*Set max protect voltage
Note:4)*to 13)*settings are only for DEFAULT battery type.
1)Set system time
System time format is “20YY-MM-DD-HH-MM-SS”, press“Up”or“Down”to
change the 1
st
digit,press “OK” to switch to next digit,press “OK” to complete
setting. When system time setting is complete, “Set country” will pop up.
2)Set country
Press “Up” or “Down” to select a country, press “OK” to complete the country
setting. When country setting is complete, “Set battery type” will pop up.
Code
Country
Code
Country
Code
Country
00 Germany VDE4105 14 Germany VDE0126 28
Brazil
01
CEI-021 Internal
15
CEI-016 Italia
29
Slovakia VSD
02
Australia
16
UK G98
30
Slovakia SSE
03
SpainRD1699
17
Greece island
31
Slovakia ZSD
04
Turkey
18
EU EN50438
32
CEI0-21 In Areti
05
Denmark
19
IEC EN61727
33
Ukraine
06
Greece Continent
20
Korea
34
Brazil LV
07
Netherland
21
Sweden
35
Mexio LV
08
Belgium
22
Europe General
36
FAR Arrete32
09
UK G99
23
CEI-021 External
37
Denmark TR322
10
China
24
Cyprus
38
Wide-Range-60HZ
11
France
25
India
39
Ireland EN50438
12
Poland
26
Philippines
13
Germany BDEW
27
New Zealand
This inverter (offer to Australian Market) has Volt-watt modes enabled by default.
Volt-var settings can be enabled by enabling the country code 102 AU_VAR or