SUNSYS B15-B20

Summary of Contents for SUNSYS B15

Page 1: ...Installations und bedienungsanleitung DE Manuel d installation et d utilisation FR Installation and operating manual GB Manuale di installazione e uso IT SUNSYS B15 B20 ...

Page 2: ...r electronic mail assistenza socomec com or fax 390444 598626 In all cases the report submitted to the above Department must be accompanied by a brief description indicating the type of fault product serial number and all details on the ID plate A copy of the proof of purchase document must be attached to the written report delivery note invoice till receipt stating the purchase date and product I...

Page 3: ...s and standards b Similarly the warranty will be invalidated I if the defective product and or component is not returned to Sicon S r l in its original packaging or equivalent II if the serial number identifying the products has been tampered with or is not clearly identifiable III if the defect concerns aesthetic or construction aspects that do not affect normal product operation c The warranty d...

Page 4: ......

Page 5: ...NS 13 5 1 DESCRIPTION 13 5 2 AC CONNECTION 15 5 3 DC CONNECTION 16 5 4 COMMUNICATION MODULE CONNECTIONS 16 6 COMMISSIONING 18 6 1 PHOTOVOLTAIC MODULE SETUP 18 6 2 AC GRID VOLTAGE REQUIREMENTS 18 6 3 FIRST START UP 19 7 CONTROL PANEL 20 8 MENU 21 8 1 DESCRIPTION 21 8 2 SETTINGS 24 9 MEASUREMENTS AND MESSAGES 30 9 1 MEASUREMENTS 30 9 2 ERROR MESSAGES 31 9 3 WARNING MESSAGES 32 9 4 FAULT MESSAGES 32 ...

Page 6: ... carrying out any operations on the inverter read the Installation and Operating Manual carefully The following precautions must be taken in order to avoid risks of overheating fire electric shock mechanical shock and collateral damage persons and or property Do not cover or obstruct the air outlet vents Do not install the inverter inside a cabinet in an enclosed non ventilated area When installin...

Page 7: ...nsure that the data plate details on the left hand side of the inverter correspond to those of the model purchased all accessories are included in the package WARNING If the inverter is found to be damaged externally or internally or any of the accessories are damaged or missing contact SOCOMEC 67 2 kg 1 2 3 INSTALLATION AND OPERATING MANUAL 2 2 CONTENTS WARNING The inverter must be lifted by two ...

Page 8: ...rrent AC Output Voltage Current Power 0 CLASSIlCATION Over voltage category Safety class SUN PR18KTL65RP 200 1000Vdc Max power 350 800 Vdc max 23A X 2 400 Vac 3PH 50 Hz max 25 A 15 kVA max 15 75 kVA cosM 0 8 ind 0 8 cap IP 65 3 1 Assembled in China S N WD12230012 WD12230012 Model DC Input Voltage Current AC Output Voltage Current Power 0 CLASSIlCATION Over voltage category Safety class SUN PR24KTL...

Page 9: ...9 SUNSYS B15 B20 Ref IOMSUNPRXX03 GB 00 ENGLISH 3 1 1 3 DESCRIPTION 3 1 DIMENSIONS 336 2 208 5 288 1 952 1047 5 Front view Side view Rear view View from above View from below ...

Page 10: ...NPRXX03 GB 00 10 3 2 1 3 DESCRIPTION 3 2 GENERAL DESCRIPTION OF COMPONENTS Air outlet vent Label showing data and standards LCD display and control panel Input connection Communication port Output connection Fans Earth connection ...

Page 11: ... The wall must be sound and completely smooth Install the inverter in an equipment room where only skilled technicians have access The room must be of a suitable size clean free from inflammable items not exposed directly to sunlight maintained at a temperature between 18 C and 40 C 4 2 CONDITIONS FOR INSTALLATION 4 2 1 ...

Page 12: ...UNPRXX03 GB 00 12 4 INSTALLATION 4 3 WALL FIXING 4 2 2 Suitable installation clearances 60 cm 60 cm 60 cm 60 cm 60 cm 60 cm 60 cm 4 3 1 14 3 82 x 6 492 82 30 Unità di misura mm 6 viti M6 Parete 30 97 8 129 192 8 6 viti M6 127 7 ...

Page 13: ...o the inverter check that the polarity voltage and sequence of the phases are correct Check that the input and output cables of the photovoltaic system are clearly identified PV module inputs 1 4 DC1 2 strings in parallel DC2 2 strings in parallel Inverter cooling fans External earth connection PE Three phase AC output with connections L1 L2 L3 and PE External communication interface ...

Page 14: ... two separate inputs 2 MPPT DC1 DC2 1 L1 2 L2 3 L3 4 N PE o z z Photovoltaic panels Photovoltaic panels Must be connected in parallel A transformer must be installed Isolating transformer Load 3 Ph N 400 Vac Inverter 3 Ph N 400 Vac AC connections Parallel or Separate DC connections External communication interface DC distribution panel DC distribution panel GND or GND Note with a floating DC input...

Page 15: ...n the table Sizing of AC cables Model Rated current Cross section Fastening Circuit breaker Residual current protection SUNSYS B15 22 A 6 mm2 0 9 Nm MCCB rated 32 A 3P N curve C 0 3 A type A or AC SUNSYS B20 29 A 6 mm2 0 9 Nm MCCB rated 40 A 3P N curve C 0 3 A type A or AC The AC connection is made with a three phase plug L1 L2 L3 N PE see drawing 5 2 1 1 L1 2 L2 3 L3 4 N PE PE L2 L1 L3 N 2 1 4 3 ...

Page 16: ...C connections are divided into positive and negative poles 5 4 COMMUNICATION MODULE CONNECTIONS 5 4 1 Communication module red black Dry contact 10 A 250 V EPO Emergency Power Off RS485 RS485 Terminal resistor PIN Layout PIN FUNCTION 4 DATA 5 DATE 7 GND 5 4 1 EPO Connector CNS3 performs an emergency power off function EPO When the external breaker is short circuited the inverter shuts down immedia...

Page 17: ...8 Stop bit 1 Parity N A RS485 Pin 1 2 3 4 5 Function DATA DATA GND Terminal resistor Resistor Pin 1 2 ON ON OFF OFF OFF OFF 5 4 3 RS 485 The RS 485 function enables connection of the inverter in parallel Installation set the dip switch SWS1 of the first and last machine in the series to the ON position this same dip switch must be set to the OFF position on all other machines WARNING If the termin...

Page 18: ...imum short circuit current 32 A SUNSYS B20 or 24 A SUNSYS B15 The voltage range of the MPPTs must be between 350 V and 800 V 6 2 AC GRID VOLTAGE REQUIREMENTS Nominal voltage and current See Chapter 5 An AC1 automatic circuit breaker must be installed and allocated to each of the solar inverters independently of the system see heading 5 2 Grid voltage values L1 L2 400 Vac L1 N 230 Vac L1 L3 400 Vac...

Page 19: ...P RXQWU 12 Lug 2012 14 37 Are you sure xxxxxx Country No Yes SET SET EXIT Select Language 12 Lug 2012 14 37 Deutsch Français English Italiano Español Nederlands SET Machine settings Menu 12 July 2012 14 37 Power Meter Energy Log E Today Event Log Operation Data Inverter Information Settings Daily energy produced Electrical measurements Energy data log Event log Operating data About the inverter 6 ...

Page 20: ...een LED Red LED Countdown FLASHING OFF On grid LIT OFF Error or fault OFF LIT Standby or night time no DC supply OFF OFF One DC input only during countdown 1 OFF FLASHING One DC input only inverter delivering LIT FLASHING Fan fault2 LIT FLASHING FW update FLASHING FLASHING 1 Solar Low alert inverter not connected to grid 2 HW Fan alert Back to previous page LCD display Scroll down Scroll up LED gr...

Page 21: ...54 W P 600 620 230 V V 1 7 1 3 7 6 A I E Today 47kWh 12 July 2012 14 37 Runtime 8 2 Hrs Power 12103 W On Grid 20 15 10 5 4 8 12 16 20 24 0 Power curve Input DC2 Input DC1 Power Voltage Current Instantaneous power output Energy produced Daily hours of operation Inverter status AC output 8 MENU WARNING The menus and settings described are visible only after the appliance has been started up for the ...

Page 22: ...nth Earning Month CO2 Saved 1240 2690 kg E Month Peak Day 2480 95 kWh kWh Month Earning Month CO2 Saved 1240 4612 kg Exit 2010 05 Day E Day Peak Hours 80 14 kWh kWh Day Earning Day CO2 Saved 40 149 kg E Day Peak Hour 80 14 1 kWh kWh Day Earning Day CO2 Saved 40 149 kg Exit 2010 06 20 Year EXIT EXIT EXIT EXIT EXIT Energy Log Month 12 July 2012 14 37 Energy Log Day 12 July 2012 14 37 Energy Log Year...

Page 23: ...perating Data 3 4 12 July 2012 14 37 Output Voltage Current Power Frequency Vdc A W Hz Maximum 247 30 5 20311 5010 Operating Data 2 4 12 July 2012 14 37 Voltage Vdc Current A Power W Voltage Vdc Current A Power W Voltage Vdc Current A Power W L1 L2 L3 Maximum 247 30 5 6810 244 30 3 6756 245 30 1 6745 8 MENU 8 1 6 Inverter information Inverter Information 12 July 2012 14 37 Serial Number DSP Versio...

Page 24: ...DFWLYH 3RZHU RQWURO 3HUVRQDO 6HWWLQJV 57 12 07 2012 DD MM YYYY 13 50 English 5 min 3 2 Personal Settings 12 July 2012 14 37 Language Date Time Screen Saver Brightness Contrast 8 2 3 Coefficient settings RHIðFLHQW 6HWWLQJV 12 July 2012 14 37 1 86 0 50 DUQLQJ 9DOXH Z N K 2 6DYHG J N K XUUHQF 5 60 minutes automatic shut down 1 5 8 2 SETTINGS 8 MENU ...

Page 25: ...rid settings Grid setting The operating voltage and frequency thresholds of the inverter are displayed Reconnection time This function varies the waiting time for the inverter to restart factory setting 300 s Ramp up Power Percentage of rated power put onto the grid during start up factory setting 20 8 2 1 Installation settings WARNING DAMAGE CAN BE CAUSED TO THE MACHINE AND SYSTEM The following s...

Page 26: ...verter information Settings EXIT SET SET SET 8 2 2 1 Active Reactive Power 12 July 2012 14 37 Power vs Frequency Power Limit Constant cosM cosM P Constant Reactive Power Q U Active Power Control 12 July 2012 14 37 Rated OFF 100 Actual Rated Power Mode Set Point EXIT SET 8 2 2 3 Frequency determined Active Power Control This function limits the active power output level automatically in the event o...

Page 27: ...nitoring If activated this function generates a cosφ variable as a function of power instantaneous power factor regulated automa tically by the inverter Active Reactive Power 12 July 2012 14 37 Power vs Frequency Power Limit Constant cosM cosM P Constant Reactive Power Q U V 1 00 45 Ind 0 90 90 241 5 Reactive Power Control 12 July 2012 14 37 Lower Power Upper Power Lower limit cosM Lock in Voltage...

Page 28: ...ctive Power Q Sn EXIT SET 8 2 2 7 Operation at voltage regulated reactive power Q This function generates reactive power determined by the voltage registered at the output terminals Active Reactive Power 12 July 2012 14 37 Power vs Frequency Power Limit Constant cosM cosM P Constant Reactive Power Q U Controllo potenza reattiva 12 July 2012 14 37 V2s V1s Qs limit V2i V1i Qi limit V V 248 4 253 0 I...

Page 29: ...will not shut down during dips in grid voltage 8 2 2 8 Settings 12 July 2012 14 37 RHIðFLHQWV 6HWWLQJV QVWDOO 6HWWLQJV FWLYH 5HDFWLYH 3RZHU RQWURO 3HUVRQDO 6HWWLQJV 57 57 12 July 2012 14 37 PV V HDG EDQG 9 HDG EDQG 9K N IDFWRU 9GURS W 8 W SET SET EXIT 57 12 July 2012 14 37 V ON Mode t3 EXIT 3DVVZRUG 12 July 2012 14 37 8 MENU ...

Page 30: ...tion Total CO2 saved Total reduction in CO2 emissions since the system went into operation Energy year Total energy produced in one year Earnings year Total earnings in one year Monthly peak Peak production per month CO2 year Total reduction in CO2 emissions over one year Energy month Total energy produced in one month Earnings month Total earnings in one month Daily peak Peak production per day C...

Page 31: ...n Grid Quality 1 Excessive distortion caused by loads connected to grid or near inverter 2 Measuring circuit failure 1 Check for the existence of non linear loads connected to the grid 2 Contact the technician HW Connected Fail 1 AC plug wrongly connected 2 Measuring circuit failure 1 Check the wiring as described in the manual 2 Contact the technician No Grid 1 No AC power 2 AC switch contacts op...

Page 32: ...0 C 2 Measuring circuit failure NTC2 1 Check the installation environment 2 Contact the technician HW NTC3 Fail 1 Ambient temperature 90 C or 30 C 2 Measuring circuit failure NTC3 1 Check the installation environment 2 Contact the technician HW NTC4 Fail 1 Ambient temperature 90 C or 30 C 2 Measuring circuit failure NTC4 1 Check the installation environment 2 Contact the technician HW DSP ADC1 1 I...

Page 33: ...ician 3 Compare machine and grid measurement values Bus Unbalance 1 Problems with wiring of strings 2 String short circuiting to earth 3 Internal control circuits not working 1 Check the parallel string setup connected to the inverter 2 Check the system 3 Contact the technician HW Bus OVR 1 Problems with wiring of strings 2 String short circuiting to earth 3 Internal control circuits not working 1...

Page 34: ...ction 1 2 The solar inverter should be inspected at six monthly intervals to ensure continued trouble free operation To ensure the appliance is properly ventilated check the fans are operating correctly and the protective air vent grilles are clean 10 1 REMOVAL OF FAN MOUNTING PLATE 1 2 3 4 1 4 5 2 3 ...

Page 35: ...35 SUNSYS B15 B20 Ref IOMSUNPRXX03 GB 00 ENGLISH 10 3 1 10 2 1 10 MAINTENANCE 10 2 FAN REPLACEMENT 1 4 2 3 NEW 10 3 REMOVAL OF AIR OUTLET VENT GRILLES ...

Page 36: ...disconnect the electricity 2 Isolate the power feed from the photovoltaic field 3 Use a suitable meter to verify the absence of AC and DC voltages 4 Remove the AC connections immediately 5 Remove the DC connections to isolate the PV field 6 Remove the RS485 communication module with the computer connection Once these steps have been completed remove the inverter ...

Page 37: ...tart up voltage 250 V Start up power 40 W Absolute maximum voltage 1000 VDC MPP voltage range at rated power 350 800 Vdc Number of inputs 4 2MPPT MPPT Parallel inputs 1MPPT Separate inputs 2MPPT Separate inputs 2MPPT 30 A 23 A Rated current 2 x 30 A 2 x 23 A AC output grid side Rated power at 400 V 10 20 kVA 15 kVA Rated power at Cosφ 0 9 18 kW 13 5 kW Maximum power 21 kVA 15 75 kVA Voltage 230 40...

Page 38: ...ime clock 30 events External communication 2 x RS 485 connection Standards and Directives CE compliance Yes Emissions IEC61000 6 4 IEC61000 6 3 Harmonics EN 61000 3 12 Fluctuations and flicker EN 61000 3 11 Grid interface VDE0126 1 1 RD1663 Immunity ESD IEC 61000 4 2 RS IEC 61000 4 3 EFT IEC 61000 4 4 SURGE IEC 61000 4 5 CS IEC 61000 4 6 PFMF IEC 61000 4 8 Electrical safety EN 60950 Draft IEC62109...

Page 39: ......

Page 40: ...x SOCOMEC Strasbourg 11 route de Strasbourg B P 10050 F 67235 Huttenheim Cedex FRANCE Tel 33 0 3 88 57 45 45 Fax 33 0 3 88 74 07 90 SOCOMEC Isola Vicentina Via Sila 1 3 I 36033 Isola Vicentina VI ITALY Tel 39 0444 598611 Fax 39 0444 598622 it pvconsult socomec com www socomec com IOMSUNPRXX03 GB 00 IOMSUNPRXX03 GB 00 11 2012 ...