The Status signal from SPR2 is sent to the Accu wire of SPR3. This continues further backwards in the 
system.

Onward transport

Outlet starts when the transmitter is switched off/opened (this means when the front carton is removed 
or product stop is lowered). SPR1 starts after 1.5 seconds.

When SPR1 has accelerated (after yet another 1.5 seconds) it switches off its Status signal. This is 
registered in SPR2, which starts after 1.5 seconds. This continues further backwards in the system.

5.6 Configuration of zero pressure accumulation

The length of the zone is determined by the length of the longest item to be conveyed plus approximately 
100 mm depending on deceleration time and required distance between items. 

If possible, remove the belt drive on one or two non-driven rollers between 2 zones so that an 
accumulated item can never be placed on a driven roller in the neighbouring zone. This will give more 
flexibility between short and long, heavy and light items. 

A transmitter is placed in each zone approximately 100-150 mm before the outlet end of the zone.
The distance is chosen so that the heaviest item to be conveyed has time to brake within the zone.

Place the 6 DIP-switches on the PSB terminal strip printed circuit board in position “Off”.

Design of “red stop light”

Whether items are to be accumulated or be led straight through is determined by the connection between 
terminals 13 and 14 on KL1 in PSB1. A jumper or an external contact signal can be inserted between 
them depending on the application. This is described below.

Accumulation

Item no. 1 activates S1, and SPR1 stops. SPR1 sends a signal to SPR2 to stop when S2 is activated by 
item no. 2. This continues further backwards in the system.

Onward transport

If item no. 1 is removed manually or automatically:

- When the item is removed S1 switches off and SPR1 and SPR2 start. 
- Item no. 2 then leaves SPR2 and stops at S1. 
- When S2 is no longer activated, SPR3 starts, and this continues further backwards in the system.

This function is made by inserting a jumper between terminals 13 and 14 on KL1 in PSB1.

If an item with a too low weight arrives at the accumulation section, the pressure accumulation 
principle will not function, and zero pressure accumulation must be used. 

Summary of Contents for S491800510

Page 1: ...9724740011_2008 12 17_SPR_GB www socosystem com MANUAL SOCO Power Roller SPR...

Page 2: ...Safety 4 2 1 Safety in general 4 2 2 Disposal 4 3 Survey 5 3 1 Survey of SPR 5 4 Operation application and compatibility 6 4 1 Operation 6 4 2 Application 6 4 3 Compatibility 7 5 Accumulation systems...

Page 3: ...s manual contains all information relating to safety required in connection with installation operation and maintenance of the product This is a standard manual and changes may have been made in conne...

Page 4: ...uld not be disposed of as unsorted municipal waste Please utilize your local WEEE collection facilities in the disposal of this product and otherwise observe all applicable requirements Our products c...

Page 5: ...gh power supply White 2 Direction Required direction of rotation To SPR 0 VDC anti clockwise seen from the supply end of the roller 24 VDC clockwise seen from the supply end of the roller Grey 6 Accu...

Page 6: ...to its accumulation current limit If the motor stops due to exceeding of the current limit 24 VDC is switched to its Status wire The signal is reset to 0 VDC when the motor has started again 4 2 Appl...

Page 7: ...Stop are then to be controlled by means of the yellow Status wire Note 0 VDC Start 24 V DC Stop The direction of rotation of the motor is changed by switching 24 V DC to the white Direction wire e g b...

Page 8: ...roller conveyor into equally large zones A zone consists of an SPR and a number of non driven rollers The non driven rollers are driven by an SPR by means of a belt drive If the zone is to have zero...

Page 9: ...exceeds nominal current when the item is blocked This means that factors such as base dimensions number of non driven rollers and the rolling friction paper quality of the transported item are also im...

Page 10: ...or the like with a 24 V DC PNP outlet The transmitter is connected to PSB1 terminal strip KL1 according to diagram Examples If items are removed automatically or manually from the accumulation convey...

Page 11: ...tems A transmitter is placed in each zone approximately 100 150 mm before the outlet end of the zone The distance is chosen so that the heaviest item to be conveyed has time to brake within the zone P...

Page 12: ...yance of items Connect an external contact signal between terminals 13 and 14 on KL1 in PSB1 When the contact signal is opened SPR1 starts and item no 1 is conveyed onward When S1 is no longer activat...

Page 13: ...nute How is the roller used Pressureless accumulation pressure accumulation or continuous accumulation Error Action SPR does not rotate Check wires from the roller visually Is the cable damaged or has...

Page 14: ...O SYSTEM GmbH Graf Zeppelin Strasse 12 46149 Oberhausen Germany Tel 49 208 629 350 Fax 49 208 629 3511 E mail info socosystem de Hungary SOCO SYSTEM EED KFT Eastern Europe Division 1031 Budapest Z hon...

Reviews: