MV-805 IP Multiviewer User Manual
TSL Template
RollCall Templates 6.4
Issue1 Revision 1
Page 64
© 2018 SAM
6.4 TSL Template
The RollCall TSL template allows configuration of settings related to support of the TSL
protocol.
TSL protocol is supported in TSL Server Mode or TSL Client Mode.
For two types of ethernet protocols (UDP and TCP), the user can separately set up IP
address and network port information:
Figure 41 RollCall TSL Template
Setting
Description
UDP settings:
Ethernet Interface
Drop-down box.
Select which network interface of the MV-805 unit to use.
Note:
Typically, the “Control” network interface is used and
not
a media network
interface.
3.1 Port
Text box.
Enter the network IP port to receive TSL 3.1 messages on.
Remember to press the
S
button to save the change.
5.0 Port
Text box.
Enter the network IP port to receive TSL 5.0 messages on.
Remember to press the
S
button to save the change.
Mode
Drop-down box.
Select
Server
mode, or ‘disabled’.
TCP settings:
IP Address
Text box.
For
Server
Mode
:
Enter the local IP address of the MV-805 network interface connected to the
TSL controller.
For
Client
Mode
:
Enter the IP address of the TSL Controller.
Remember to press the
S
button to save the change.
Table 16 TSL Mode Settings