LC2000/LC2000-IQ/LC4000/LC4000-IQ
System Setup Menus
Issue 1 Rev 6
Page 41
© 2015 SAM
7.5.4 Timing
7.5.4.1
Ch 1–4
The Timing controls enable you to specify the horizontal and vertical genlock timing.
•
Vertical Timing:
Adjusts the vertical timing of the output signal with respect to the
reference signal. The adjustment range is one output line in one-line steps. The
preset value is 0.
•
Horizontal Timing:
Adjusts the horizontal timing of the output signal with respect to
the reference signal. The adjustment range is one output frame in one-pixel steps.
The preset value is 0.
•
Status:
Shows the status of the currently assigned reference. For example, if genlock
is assigned to input 1, status shows “Ch 1 Input” followed by the current status of the
input. If there is no signal on the assigned reference, status shows “REF Loss”.