High Performance Two Port 10/100 Managed Ethernet Switch with 32-Bit Non-PCI CPU Interface
Datasheet
Revision 1.4 (08-19-08)
332
SMSC LAN9312
DATASHEET
14.5.2.11
Port x MAC Receive OK Count Register (MAC_RX_PKTOK_CNT_x)
This register provides a counter of received packets that are or proper length and are free of errors.
The counter is cleared upon being read.
Note:
A bad packet is one that has a FCS or Symbol error.
Register #:
Port0: 0418h
Size:
32 bits
Port1: 0818h
Port2: 0C18h
BITS
DESCRIPTION
TYPE
DEFAULT
31:0
RX OK
Count of packets that are of proper length and are free of errors.
Note:
This counter will stop at its maximum value of FFFF_FFFFh.
Minimum rollover time at 100Mbps is approximately 481 hours.
RC