background image

1

Sonic Start

®

 Streamline

tm

 for PiSta

®

retrofit kit - 1 PumP 

reorder #H67a253

installation & operation  

instructions

Smith & Loveless Inc.

Thank  you  for  purchasing  the  Smith  &  Loveless,  Inc.  patent-pending 

Sonic Start

®

 Streamline

tm

  for 

PiSta

®

 

R

etrofit Kit, S&L Part 

No. H67A253. This Kit has all of the parts required to convert your Top 

Mounted 

PISTA

®

 Turbo Grit Pump from electrode to the 

Sonic Start

®

 

Streamline

tm

 Vacuum Priming System. 

®

Part #: 67P2

PN: H67A253

Summary of Contents for H67A253

Page 1: ...less Inc Thank you for purchasing the Smith Loveless Inc patent pending SONIC START STREAMLINETM for PISTA Retrofit Kit S L Part No H67A253 This Kit has all of the parts required to convert your Top M...

Page 2: ...uation which if not avoided could result in death or serious injury These signs appear with an orange background and black letters CAUTION Indicates a potentially hazardous situation which if not avoi...

Page 3: ...6L30K Nuts 7 1 1L546D Elbow Tubing Connector 8 2 1L460D Male Tubing Connector 9 15 ft 1L142BC Tubing 10 6 5L150A Cable Ties 11 1 67P2 Installation Instructions This Document not shown Parts included i...

Page 4: ...ponents are required use kit PN H67A254 For a heated and insulated cover down to 300 F for the dome and solenoid valve assembly order the STREAMLINE Jacket kit PN H67A262 Before starting check the exi...

Page 5: ...n the Sonic Start Prime Sensing System DANGER Disconnect and lock out power before servicing the equipment Failure to do so could result in electrical shock serious bodily injury or death Step 2 Disco...

Page 6: ...ill not seal and will create a vacuum leak Step 4 Mark the location for the SONIC START Probe Item 1 on the motor adapter See Diagram 2 for the correct location of the SONIC START Probe Item 1 Use a h...

Page 7: ...ONIC START Probe Item 1 into the tapped hole to test the depth of the tapped hole The shoulder of the SONIC START Probe Item 1 must be or less from the motor adapter to have proper thread engagement s...

Page 8: ...C START Probe Item 1 threads Make sure the Teflon tape covers the threads as shown in Photo 9 Thread the SONIC START Probe Item 1 into the tapped hole Place the SONIC START Fitting Ring Item 1A onto t...

Page 9: ...and connect it to the SONIC START Probe s Item 1 and Skip to Step 41 If you have an electrode dome remove the cord grip and grommet portion of the Sonic Start Probe s electrical fitting Item 1C See P...

Page 10: ...electrical fitting can now be wired See Photo 15 Take one end of new electrical wire not supplied with this kit and connect one Power wire to Pin 1 a second Power wire to Pin 2 and the Ground wire to...

Page 11: ...mine how your installation is currently wired for either the Electrode or SONIC START Probe Item 1 Wiring connections are dependent upon what your unit has currently installed Your new conduit and wir...

Page 12: ...ocket Photo 19 Step 19 Nowrunconduit notincludedinthiskit fromthe Sonic Start Probe s electrical connector Item 1C to the panel with the Electrode Relay or Sonic Start Operating Module socket In Step...

Page 13: ...ld result in electrical shock serious bodily injury or death WARNING All electrical work should be performed by a qualified electrician and per all applicable codes Failure to do so may result in seve...

Page 14: ...y 1 in Photo 22 use steps 21 to 24 Relay 1 Photo 22 but keep any other wires connected to pin 1 or pin 8 Do not reuse any wires with a resistor capacitor or diode Step 21 Remove the clear relay from i...

Page 15: ...r connections with the same number as the wire terminated on the load secondary side of the control circuit breaker Step 23 Run the wire from Pin 1 of the SONIC START Probe s electrical fitting Item 1...

Page 16: ...y wires from pins 3 and 4 Typically they are connected to the terminal strip Consult your wiring diagram for the correct wire number Step 26 Remove the wire from pin 2 and connect it to the wire from...

Page 17: ...p 29 Move any wire s from Pin 7 to Pin 5 These pins are on the opposite side of the socket so it may be necessary to run a new wire or to wire nut another piece of wire onto it to reach Step 30 If the...

Page 18: ...r and see what wire number is terminated on the load sec ondary side of the control circuit breaker Run a wire from Pin 7 of the socket to one of the terminal blocks or other connections with the same...

Page 19: ...res from Pins 6 and 8 Typically they are connected to the terminal strip Consult your wiring diagram for the correct wire number Step 34 Remove the wire from Pin 2 and connect it to the wire from Pin...

Page 20: ...in 1 Step 39 Look at the control circuit breaker and see what wire number is terminated on the load sec ondary side of the control circuit breaker Run a wire from Pin 7 of the socket to one of the ter...

Page 21: ...oleum jelly or non pumice hand soap to the o ring at the bottom of the new SONIC START STREAMLINE vacuum dome assembly Item 3 See Photo 27 This will make it easy to install the dome into the motor ada...

Page 22: ...ep 45 Install the washers Item 5 and nuts Item 6 onto the mounting studs to secure the compression ring see Photo 31 Step 46 NowwiretheSONICSTART STREAMLINE solenoid valve First install a conduit body...

Page 23: ...e vacuum priming panel Step 48 Splice new wires onto the leads coming out of the SONIC START STREAMLINE solenoid valve on the SONIC START STREAMLINE vacuum dome assembly Item 3 to the wire you will ru...

Page 24: ...the correct wire numbers Step 52 Locate the old vacuum priming solenoid valve Disconnect and remove it The old solenoid valve will be located in the vacuum priming line between the Top Mounted PISTA T...

Page 25: ...bulkhead fitting Keep the bulk head fitting installed Now install a male tubing connector Item 8 to each side of the bulkhead fitting both inside and outside of the panel see Photos 39 40 Step 55 Ins...

Page 26: ...e any remaining vacuum tubing from the previous system that is not being used in the Sonic Start Streamline for PISTA Vacuum Priming System Step 59 Perform a final check to make sure everything is com...

Page 27: ...s primed Electrical Problems Indicating Light A flashing Red light means that there is an overload or short circuit in the SONIC START wiring or a problem with the SONIC START Prime Sensing Probe See...

Page 28: ...the leak take the connection that is leaking apart and put Teflon tape or other thread sealant on the male fitting and reassemble 4 Check the solenoid valve to make sure it is not clogged or filled w...

Page 29: ...the problem then switch out the SONIC START Prime Sensing Probe itself The Troubleshooting 3 If the pump runs but it is not primed and the Green indicating light is On and the Red indicating light is...

Page 30: ...of the wiring items and it does not correct the flashing Red light then check the wiring Make sure the wiring is attached to the SONIC START Prime Sensing Probe If it was not securely connected and no...

Page 31: ...cement Retrofit Kit parts are the responsibility of Owner SMITH LOVELESS will not assume responsibility for the cost of any repairs or Warranty Part Description 4L628F Sonic Start Sensor 4L264S Sonic...

Page 32: ...th Loveless Inc 14040 Santa Fe Trail Drive Lenexa KS 66215 1284 USA Ph 800 922 9048 Fax 913 748 0106 www smithandloveless com E mail answers smithandloveless com Part 67P2 Smith Loveless Inc 2010 2 23...