Power supply ICOS-PS 3160 series
Installation, use and maintenance manual - EN
Ver. 1.05
36
5.8.2 Interface I/Os
The power supply unit features a digital input (RESET) and two outputs (POWER GOOD and ALARM). They
allow to interface the unit with external devices (such as a PLC). In this way, it is possible to know if the power
supply unit is ready to operate and the user can reset some error conditions.
The following drawing shows how to make correct connections:
These inputs and outputs are suited for 24V digital signals, in order to be able to interface with standard in-
dustrial electronics (in particular PLCs).
24V
GND
PSU
24V
GND
RESET
POWER GOOD
ICOS-PS
PLC
ALARM