![Smitec Cosmos 315 Series Installation, Use And Maintenance Manual Download Page 90](http://html.mh-extra.com/html/smitec/cosmos-315-series/cosmos-315-series_installation-use-and-maintenance-manual_1305308090.webp)
COSMOS DRIVER SERIES 3000 - USE AND MAINTENANCE MANUAL
10 Error codes (FLxIO, Sercos III and Modbus TCP)
The drivers COSMOS 3000 include two series of error codes: one for the errors deriving from the control board and one
for the errors deriving from external causes or from the power section.
10.1 Internal errors
These errors derive from the control circuits or from the firmware. They indicate critical problems which imply the stop of
all the driver activities.
The error code is represented exclusively on the status LEDs (not on VISIO), according to the modes specified in chapter
Cod.
Error
Description
01
FATAL_ERROR_INT_RAM
Error in the test of the internal RAM
02
FATAL_ERROR_INT_FLASH
Error in the test of the internal FLASH
03
FATAL_ERROR_EXT_RAM
Error in the test of the external RAM
04
FATAL_ERROR_EXT_FLASH
Error in the test of the external FLASH
05
FATAL_ERROR_ILLEGAL_OP
SW/HW error in the execution of the CPU instructions
06
FATAL_ERROR_ADDRESS
SW/HW error in the execution of the CPU instructions
07
FATAL_ERROR_NMI
Unexpected, non maskable interrupt HW
08
FATAL_ERROR_BANK
SW/HW error in the system interrupt control
09
FATAL_ERROR_MATH
SW/HW error in the execution of the CPU instructions
10
FATAL_ERROR_TRAPA
Unexpected interrupt SW
11
FATAL_ERROR_INT
Unexpected, maskable interrupt HW
12
FATAL_ERROR_TASK
Task creation OS error
13
FATAL_ERROR_RESOURCE
Resource allocation OS error
14
FATAL_ERROR_HW_TEMP
Internal temperature beyond the limits (>85°C)
15
FATAL_ERROR_HW_VOLTAGE
Reserved
16
FATAL_ERROR_FPGA
HW error in the FPGA setting
17
FATAL_ERROR_MODESET
Reserved
18
FATAL_ERROR_INIT
Application initialization error
Ver. 1.07
Pag. 90