smirthwaite 999-1-12 User Manual Download Page 11

 

11 

INSTALLATION

 

 

 

 

Main Control Box 

Emergency Stop 

Actuator cables (left hand socket used) 

Handset cable 

Battery (removable) 

Charger 

Cable Tidy 

 

3.3  Charging 

 

The battery should be charged for at least 8 hours upon receipt by 

connecting the battery to the supplied wall mounted charger. 

  The rechargeable battery can be un-clipped from the main control box assembly on the 

Mobi Changer and placed onto the wall mounted charger. 

  A green light on the charger will indicate the charger is connected to the AC mains supply 

  A second light will light in yellow when the battery is being charged. 

  For routine use, the battery should be charged daily, for a period of 4 hours. 

  An audible alarm will sound when the battery has discharged to approximately 25% charge 

level through use. 

  Sufficient charge is held in the battery in reserve to permit emergency lowering of the bed. 

3.4  Control Box 

  An emergency stop button (RED) is situated on the control box; when depressed this halts 

the operation of the bed – to enable the Mobi Changer to operate again, simply twist the 

emergency stop button to reset 

  Duty cycle: Max 10% (or 2 minutes) continuous use, then 18 minutes without use. 

  The control box system has been designed for operating ambient temperature of +5°C to 

+40°C 

Summary of Contents for 999-1-12

Page 1: ...1 P a g e User Manual Mobi Changer...

Page 2: ...ts 8 2 1 Key Parts 8 2 2 Packaging 9 3 0 Installation 10 3 1 Adjustments 10 3 2 Electrical System Reference 10 3 3 Charging 11 3 4 Control Box 11 3 5 Raising Safety Sides 12 3 6 Raising and Lowering 1...

Page 3: ...r Serviceable Parts 19 6 8 Final Inspection 19 7 0 Cleaning 20 7 1 General cleaning 20 8 0 Service Documentation 21 8 1 Documentation Records 21 8 2 Product Configuration 21 8 3 Service Record History...

Page 4: ...this manual are subject to change without prior notice Unauthorised modifications on any Smirthwaite product may affect its safety The manufacturer will not be held responsible for any accident incide...

Page 5: ...cal laws on recycling Degree of protection provided by enclosure N1 Ingress of particles N2 Ingress of water Temperature range Humidity range Type B applied part Type BF applied part Medical Device Au...

Page 6: ...lity environment as well as the home health care environment The Mobi Changer is not intended to be used in environments where there are rapid changes in the environmental temperature and humidity dur...

Page 7: ...patient is on the table When storing the product vertically up position check to ensure that the locking plunger pin is fully engaged When not in use for periods of time isolate the electrical supply...

Page 8: ...lways turn hand wheels levers and screws clockwise to tighten or anti clockwise to loosen Conveniently packaged in a single box the following components are included with your new Mobi Changer Illustr...

Page 9: ...ur order has been supplied as a custom kit please ensure you follow both the instructions documented in this user manual and any additional instructions supplied Please take note of any instructions o...

Page 10: ...ts To lock apply foot to point A to unlock apply foot to point B 3 2 Electrical System Reference The Mobi Changer is supplied with a control box mounted to the end of the lower frame a rechargeable ba...

Page 11: ...ight will light in yellow when the battery is being charged For routine use the battery should be charged daily for a period of 4 hours An audible alarm will sound when the battery has discharged to a...

Page 12: ...6 Raising and Lowering Before transferring a patient adjust the height of the bed by using the hand controller Up and Down buttons arrows as shown opposite With the patient safely transferred onto the...

Page 13: ...afety side up and swing to horizontal position Stow the safety side under the table Lower the table to height of the wheelchair seat It is now possible to transfer the user onto the trolley Safety Sid...

Page 14: ...124 Code Stainless Steel 3141 3142 3143 3144 Max User Weight kg 227 227 227 227 Height Range mm 470 950 470 950 470 950 470 950 Length mm 1400 1600 1800 2000 Width mm 750 750 750 750 X mm 840 840 840...

Page 15: ...nce 50 500 lux Additionally as the Changing Bench is designed for indoor use only if required the user may wish to switch on room lighting Normal operating conditions 5 C to 40 C 41 F to 104 F at a re...

Page 16: ...f usability engineering to medical devices BS EN ISO 15233 1 2016 Medical devices Symbols to be used with medical device 5 4 Disposal Please observe the local laws on recycling and respect the current...

Page 17: ...ories for damage or loose connection points Check all upholstery for signs of wear and tear Check the castors are funning freely and brakes are in full working order Keep the upholstery wooden and met...

Page 18: ...nt use the service should be reduced to half the recommended period Constant and or heavy use is considered to be Daily use above 7 hours duration Weekly use above 5 days duration Monthly use above 10...

Page 19: ...Contact details are shown on the last page of this manual 6 8 Final Inspection When the service is complete Remove any waste created as part of the service from the site Confirm with the operator if t...

Page 20: ...th and water DO NOT soak immerse any part of the product in water DO NOT use solvents abrasives synthetic detergents and wax polishes ALWAYS wipe dry after use ALWAYS keep this product away from naked...

Page 21: ...and maintain a record of the original product configuration at the time of first sale Smirthwaite will not be held responsible for any subsequent changes to this configuration unless authorized to do...

Page 22: ...ory Complete this record after each service repair inspection and or maintenance Photocopy additional pages as required Product Information Model Size Date of Manufacture Serial Number Service inspect...

Page 23: ...faults due to accident neglect misuse not following the Instructions and normal wear and tear This warranty is in addition to your legal rights Goods will only be collected from the original delivery...

Page 24: ...24 Smirthwaite Ltd 16 Wentworth Road Heathfield Newton Abbot Devon TQ12 6TL Part Number 999 1 12 Rev 1 Date Jul 21...

Reviews: