48 - INSTALLATION
914779706/B
Fixed connection
Fit the power line with an all-pole circuit breaker
with a contact separation distance sufficient to
provide complete disconnection in category III
overvoltage conditions, pursuant to installation
regulations.
Power control menu (for installer
only)
The power control menu allows you to set the
maximum power supplied by the appliance.
To access the menu:
1. Disconnect the appliance from the mains
power supply.
2. Reconnect the appliance to the mains
power supply.
3. Within 1 minute, briefly touch the lower right
and left corners of the display at the same
time:
The following screen appears:
Use your finger to scroll through the available
power settings, which can be selected in 0.1
kW steps. (Eco-Logic Advance function).
• Press
to confirm the selection.
• Press
to cancel.
In both cases, you exit from the power control
menu and return to the screen showing the
current time. On this screen, you can access the
power control menu again by following the
instructions in point 3.
Section cut from the countertop
Safety instructions for positioning and
installation
• Installation can be carried out on various
materials such as masonry, metal, solid
wood or plastic laminated wood as long as
they are heat resistant (>90°C).
• Veneers, adhesives or plastic coatings on
220-240 V 3~ / 380-
415 V 2N~
4 x 4 mm ²
four-core cable
220-240 V 1N~
5 x 4 mm ²
five-core cable
The values indicated refer to the cross-
section of the internal conductor.
The aforementioned power cables are
sized taking into account the
coincidence factor (in compliance with
standard EN 60335-2-6).
For all types of connection, use the
jumper provided.
You can set the value from a minimum of
2.4 kW to a maximum of 11.0 kW; the
latter is the value pre-set at the factory.
The power control menu closes
automatically after 2 seconds of
inactivity.
See General safety instructions.