Installation
87
EN
floor. The feet have a maximum excursion of
10 mm.
5.2 Electrical connection
General information
Check the grid characteristics against the
data indicated on the plate. The
identification plate bearing the technical
data, serial number and brand name is
visibly positioned on the appliance.
Do not remove this plate for any reason.
Perform the ground connection using a wire
that is 20 mm longer than the other wires.
The appliance can work in the following
modes:
•
220-240 V 2
~
3 x 6 mm²
three-core
cable.
•
3220-240 V 3
~
4 x 4 mm²
four-core
cable.
•
220-240 V 1N
~
3 x 6 mm²
three-core
cable.
Power voltage
Danger of electrocution
• Have the electrical connection
performed by authorised technical
personnel.
• Use personal protective equipment.
• The appliance must be connected to
earth in compliance with electrical
system safety standards.
• Disconnect the mains power supply.
• Do not pull the cable to unplug the
appliance.
• Use cables withstanding a temperature
of at least 90°C.
• The tightening torque of the screws of the
terminal supply wires must be 1.5 - 2 Nm.
Summary of Contents for TR62IBL2