Installation
49
EN
The appliance can work in the following
modes:
•
220-240 V 2
~
3 x 10 mm²
three-core
cable.
•
220-240 V 3
~
4 x 6 mm²
four-core
cable.
•
220-240 V 1N
~
3 x 10 mm²
three-core
cable.
•
380-415 V 2N
~
4 x 6 mm²
four-core
cable.
•
380-415 V 3N
~
5 x 4 mm²
five-core
cable.
Replacement clamp
In the event of connection to a two- or
three-phase supply, the installed clamp must
be replaced with the one supplied in order
to ensure correct fastening of the cable.
Fixed connection
Fit the power line with an all-pole circuit
breaker in compliance with installation
regulations.
The circuit breaker should be located near
the appliance and in an easily reachable
position.
The values indicated refer to the
cross-section of the internal
conductor.
The aforementioned power cables
are sized taking into account the
coincidence factor (in compliance
with standard EN 60335-2-6).