27
6
SETUP MODE AND FUNCTIONS
The dishwasher has a set-up mode for changing the operating parameters.
The wash parameters are not password protected, but the configuration parameters are.
6.1
Entering set-up mode
Entering the USER menu
To enter the wash settings menu, hold down the DRAIN button until the control panel displays “unlo” and then
flashes “Set”: release and press the button again immediately, this accesses the USER menu.
In the USER menu you can scroll through the following options with the “A” and “B” buttons:
USER menu options
Description
SET
Sets the dishwasher parameters – see the “Set” PARAMETERS section for details
Coun
Total hours of operation counter. This parameter is read only and cannot be
modified.
This parameter is displayed on two consecutive screens. The thousands value is
followed by “t”, the units value by “u”.
To enter a specific option, press the Start/Pause button.
To return to the higher menu level, press Door Open.
SET menu
The display reads Set.
To select this option, press
.
The Set option has a variety of individual settings.
Set
PARAMETER
DESCRIPTION
POSSIBLE
USER ACTION
POSSIBLE
TECHNICIAN
ACTION
1 –
Detergent pump P1 dose.
The grams/litre are set with this parameter; the default
value is 3, equivalent to 3.6 grams/litre.
(Max value of 1, equivalent to 1 grams/litre)
Increase/decrease the value with the Select buttons.
X
X
2 –
Rinse aid pump P2 dose.
The grams/litre are set with this parameter; the default
value is 0.5, equivalent to 0.5 grams/litre.
(Max value of 10, equivalent to 1.1 grams/litre)
Increase/decrease the value with the Select buttons.
X
X
3 –
Water hardness setting
Set the hardness in °f, in steps of 5. Range: 0-65°f. The
default is 40°f.
Note: Make sure that the value corresponds to the
actual hardness of the water supply.
X
X