21 

 
 

1

 

INSTRUCTIONS FOR SAFE AND PROPER USE ____________________ 22

 

2

 

POSITIONING OF THE HOB ____________________________________ 24

 

3

 

ELECTRICAL CONNECTION ____________________________________ 26

 

4

 

GAS CONNECTION ___________________________________________ 27

 

5

 

ADAPTATION TO DIFFERENT TYPES OF GAS _____________________ 29

 

6

 

FINAL OPERATIONS __________________________________________ 33

 

7

 

USING THE HOB______________________________________________ 35

 

8

 

CLEANING AND MAINTENANCE_________________________________ 37

 

 
 
 
 
 
 
 
 
 
 
 

THESE INSTRUCTIONS ARE VALID ONLY FOR END USER COUNTRIES 

WHOSE IDENTIFICATION SYMBOLS APPEAR ON THE COVER OF THIS 
MANUAL. 

 
 

 

 

INSTRUCTIONS FOR THE INSTALLER: these are for the 

qualified 

technician 

who must carry out a suitable check of the gas system, 

install the appliance, set it functioning and carry out an inspection test. 

 

   

INSTRUCTIONS FOR THE USER: these contain user advice, 

 

description of the commands and the correct procedures for cleaning 

and maintenance of the appliance. 

 

Questo manuale d’istruzione è fornito da trovaprezzi.it. Scopri tutte le offerte per 

Smeg SRV576AL

 o

cerca il tuo prodotto tra le 

migliori offerte di Cucine e Piani cottura

Summary of Contents for SRV576AL

Page 1: ...NANCE_________________________________ 37 THESE INSTRUCTIONS ARE VALID ONLY FOR END USER COUNTRIES WHOSE IDENTIFICATION SYMBOLS APPEAR ON THE COVER OF THIS MANUAL INSTRUCTIONS FOR THE INSTALLER these are for the qualified technician who must carry out a suitable check of the gas system install the appliance set it functioning and carry out an inspection test INSTRUCTIONS FOR THE USER these contain...

Page 2: ... CONSIDERED IMPROPER THE MANUFACTURER DECLINES ALL RESPONSIBILITY FOR IMPROPER USE DO NOT LEAVE THE PACKING IN THE HOME ENVIRONMENT SEPARATE THE VARIOUS WASTE MATERIALS AND TAKE THEM TO THE NEAREST SPECIAL GARBAGE COLLECTION CENTRE IT IS OBLIGATORY FOR THE ELECTRICAL SYSTEM TO BE GROUNDED ACCORDING TO THE METHODS REQUIRED BY SAFETY RULES THE PLUG TO BE CONNECTED TO THE POWER CABLE AND THE SOCKET M...

Page 3: ...LE PLATES THAT EXTEND BEYOND THE EXTERNAL PERIMETER OF THE HOB THE HOB IS TO BE USED BY ADULTS ONLY DO NOT LET UNSUPERVISED CHILDREN PLAY WITH THE HOB THIS APPLIANCE IS MARKED ACCORDING TO THE EUROPEAN DIRECTIVE 2002 96 EC ON WASTE ELECTRICAL AND ELECTRONIC EQUIPMENT WEEE THIS GUIDELINE IS THE FRAME OF A EUROPEAN WIDE VALIDITY OF RETURN AND RECYCLING ON WASTE ELECTRICAL AND ELECTRONIC EQUIPMENT Th...

Page 4: ... is classified type Y as regards risks against fire and it can be set adjacent to walls that are higher than the work surface provided that a distance of 145 mm is respected as shown in the figure to prevent damage due to overheating Make sure there is a minimum of 750 mm between the hot plate flames and any shelf that may be installed directly above them Accurately position the gasket provided al...

Page 5: ... on a hollow compartment with doors a separating panel has to be placed under the hob Keep a minimum distance of 10 mm between the bottom of the unit and the panel surface The panel has to be easily removable to allow access in the event of technical service ...

Page 6: ...y accessible position near the unit Do not use reducers adapters or shunts If the power cable is replaced the wire section on the new cable must 2 not be less than 1 0 mm 3 x 1 0 cable keeping in mind that the end to be connected to the hob must have the ground wire yellow green longer by at least 20 mm Use only H05V2V2 F cable or similar which has a maximum temperature of 90 C Any replacement nee...

Page 7: ...en inspected for G20 2H natural gas at a pressure of 20 mbar For use with other types of gases see Section ADAPTATION TO DIFFERENT TYPES OF GAS The gas intake fitting is gas external threaded ISO 228 1 Connection with rigid copper pipe the connection to the gas mains must not provoke stress of any kind on the hob Connection may be made by using biconical adapter D with insertion of gasket C suppli...

Page 8: ...r intakes protected by screens must be appropriately sized regulations in force and placed so as not to be blocked in any way The room where the oven is installed should be suitably ventilated to avoid overheating or excess humidity produced by cooking and in the case of lengthy use a window should be opened or the speed of any ventilators should be increased 4 3 Discharge of combustion products D...

Page 9: ...zzles must be replaced and the primary air adjusted To replace the nozzles and regulate the burners you have to remove the top as described in the following paragraph 5 1 Removing the hob 1 Remove all the knobs the grids the burner caps and the flame caps 2 Remove the screws and the nuts A that secure the burner supports 3 Lift the hob from its seat 4 Replace the burner nozzles in accordance with ...

Page 10: ... of primary air and then secure the tube by means of screw A After the regulations have been carried out restore the seals with sealing wax or equivalent material Rated LPG G30 G31 28 37 mbar Burner heating capacity Nozzle Reduced diameter By pass Flowrate Flowrate flowrate 1 100 1 100 mm g h G30 g h G31 W mm Auxiliary 1 1 05 48 30 1 380 76 75 Semirapid 2 1 65 62 30 1 380 120 118 Rapid 3 2 55 76 3...

Page 11: ...irapid 2 1 65 92 380 Rapid 3 2 55 115 650 Rapid large 4 3 1 126 750 Fish pan 7 2 0 100 750 Ultra rapid 5 3 3 130 1200 Internal 1 05 73 380 Double crown 6 External 3 9 140 1200 5 4 Regulation for town gas To allow the unit to work with this type of gas perform the same operations described in paragraph 5 2 Regulation for LPG but choose the nozzles and regulate the primary air for town gas as shown ...

Page 12: ...110 30 37 mbar 8 mbar Auxiliary 1 1 5 1 0 0 5 Semirapid 2 1 5 1 5 0 5 Rapid 3 1 0 1 5 1 0 Rapid large 4 2 5 10 0 1 5 Fish pan 7 2 0 2 5 1 0 Ultra rapid 5 2 0 2 5 1 5 Internal 3 6 0 1 0 Double crown 6 External 3 0 10 0 5 0 To identify the burners on your hob refer to the drawings in point 6 3 Arrangement of burners on hob ...

Page 13: ...e model until you get a suitable minimum flame Replace the knob and check burner flame stability rapidly turning the knob from maximum to minimum position the flame should not go out 6 2 Regulation of minimum for LPG To regulate the minimum for LPG completely tighten clockwise the screw inside or next to the gas tap pin depending on the model The diameters of the by passes for each burner are give...

Page 14: ...s 1 Auxiliary 2 Semirapid 3 Rapid 4 Rapid large 5 Ultra rapid 6 Double crown 7 Fish pan 6 4 Lubrication of gas taps After a while the gas tap may become hard to turn or lock If this happens it has to be cleaned inside and re greased This must be done by a qualified technician ...

Page 15: ...s a long one corresponding to the small inner burner and a short one to the outer burner Double crown burners comprise an auxiliary and a rapid burner controlled by two different knobs which allow both burners to be used at the same time or to select one or the other as required The device is fit with electronic ignition Simply press and simultaneously turn the knob counter clockwise on the low po...

Page 16: ...at 7 3 Diameter of the pans Burners Ø min and max in cm Auxiliary 7 18 Semirapid 10 24 Rapid 12 24 Rapid large 14 26 Double crown 12 28 Ultrarapid 22 28 Fish burner Special oval shaped vessels 7 4 Using a griddle plate A few precautions are necessary if you wish to use a griddle plate leave a gap of at least 160 mm between the edge of the griddle plate and the side wall if one of the burners close...

Page 17: ...rve the surface always use specific products only which do not contain abrasive substances or chlorine based acid substances How to use pour the product on a damp cloth and wipe the surface rinse thoroughly and dry with a soft cloth or deerskin 8 1 2 Food stains or residues Do not use metallic sponges or sharp scrapers they will damage the surface Use normal non abrasive products and remove spots ...

Page 18: ...water using a non abrasive detergent taking care to remove all tough spots Before remounting allow the components to fully dry out In fact humidity residues inside the burner holes might impair burner operation 8 2 1 Ignition plugs and safety devices For good functioning of the lighting ignition plugs and the safety devices keep them very clean Check frequently and clean with a damp cloth when nec...