Installation
40
Burner and nozzle characteristics tables
The nozzles not provided are available at Authorised Service Centres.
5.3 Positioning
This appliance may be installed next to
walls, one of which is higher than the
worktop, at a minimum distance of
X
mm
from the side of the appliance, as shown in
figures “
A
” and “
C
” relative to the
installation classes.
Natural Gas G20 - 20 mbar
AUX
SR
R
UR
Rated heating capacity (kW)
1,0
1,8
2,9
4,0
Nozzle diameter (1/100 mm)
72
94
115
145
Pre-chamber (printed on nozzle)
(X)
(Y)
(Y)
(Z)
Reduced flow rate (W)
400
500
800
1600
Natural gas G25 - 20 mbar
AUX
SR
R
UR
Rated heating capacity (kW)
1,0
1,8
2,9
3,9
Nozzle diameter (1/100 mm)
77
100
134
152
Pre-chamber (printed on nozzle)
(F1)
(Y)
(F3)
(F3)
Reduced flow rate (W)
400
500
800
1600
LPG G30/G31 - 50 mbar
AUX
SR
R
UR
Rated heating capacity (kW)
1,0
1,8
2,9
3,8
Nozzle diameter (1/100 mm)
43
58
74
77
Pre-chamber (printed on nozzle)
(H2)
(M)
(Z)
(F4)
Reduced flow rate (W)
400
500
800
1600
Rated flow rate G30 (g/h)
73
131
211
291
Rated flow rate G31 (g/h)
71
129
207
286
Heavy appliance
Crushing hazard
• Position the appliance into the cabinet
cut-out with the help of a second person.
Pressure on the open door
Risk of damage to the appliance
• Never use the oven door to lever the
appliance into place when fitting.
• Avoid exerting too much pressure on the
oven door when open.
Heat production during appliance
operation
Risk of fire
• Veneers, adhesives or plastic coatings on
adjacent furniture should be temperature-