Installation

23

EN

Positioning and levelling 

•  After making the gas and electrical 

connections, screw on the four feet 
supplied with the appliance.

The appliance must sit level on the floor to 
ensure stability.
•  Screw or unscrew the bottom part of the 

foot until the appliance is stable and 
level on the floor.

1.7 For the installer

•  The plug must remain accessible after the 

installation is complete. Do not kink or 
trap the mains connection cable.

•  The appliance must be fitted according 

to the installation diagrams.

•  Do not attempt to turn or stress the 

threaded elbow on the manifold. You risk 
damage to this part of the appliance 
which may void the manufacturer’s 
warranty.

•  Before leaving check all connections for 

gas leaks with soap and water. DO 
NOT use a naked flame for detecting 
leaks.

•  Ignite all burners individually and 

concurrently to ensure correct operation 
of the gas valves, burner and ignition.

•  Turn the gas knobs to the low position 

and observe stability of the flame for 
each burner individually and all together.

•  In case the appliance fails to operate 

correctly after all checks have been 
carried out, refer to the Authorised 
Assistance Centre in your area.

•  When satisfied with the appliance, 

please instruct the user on the correct 
method of operation.

Heavy appliance

Risk of damage to the appliance

•  Insert the front feet first and then the rear 

ones.

Summary of Contents for S9GMXU9

Page 1: ...oline or other flammable vapors or liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch Do not use an...

Page 2: ...s burns to children or adults READ AND SAVE THESE INSTRUCTIONS Your safety and the safety of others are very important We have provided many important safety messages throughout this manual and on the...

Page 3: ...ange for the first time Keep these operating instructions in a safe place and pass them on to any future user NOTE This range is manufactured for use with natural gas To convert the appliance to LP Pr...

Page 4: ...70 ELECTRICAL CODE latest edition Or the CANADIAN ELECTRICAL CODE C22 11 1 and C22 2 No 01982 or latest edition and all local codes and ordinances IMPORTANT Observe all codes and ordinances in force...

Page 5: ...ppliance All adjustments and servicing must be performed by qualified installers or service technicians Do not leave the packing material around the home Sort the various items of waste and take them...

Page 6: ...0 015 0 4 mm stainless steel 0 024 0 6 mm aluminum or 0 020 0 5 mm copper 35 889 mm min clearance between the top of the cooking surface and the bottom of an unprotected wood or metal cabinet 5 max up...

Page 7: ...used in conjunction with the gas range unless the hood and range have been designed tested in accordance with ANSI Z21 1 and listed by an independent testing laboratory for combination use This type...

Page 8: ...nections should be made before the range is placed in its final position Ensure that the burner caps are correctly positioned on the burner bases on the rangetop Legs should be installed near to where...

Page 9: ...a qualified installer or contractor to determine the proper method for drilling holes through the wall or floor material such as ceramic tile hardwood etc Failure to follow these instructions may resu...

Page 10: ...s and the range has been leveled 1 Level the range using the adjustable leveling legs 2 Fasten the plates supplied to the rear of the appliance aligning them with the slits on the sides 3 From the flo...

Page 11: ...le to install the primary system After having positioned and leveled the appliance the bracket has to be anchored to the floor and engaged in the slots at the rear of the appliance 1 Assemble the fast...

Page 12: ...ct neutral lead to branch circuit neutral conductor in usual manner Do not use an adaptor Do not use an extension cord Check with a qualified electrician if you are not sure whether the range is groun...

Page 13: ...a double 20 ampere maximum circuit protection is required A time delay fuse or circuit breaker is recommended The ID Plates are visibly located on the back of the appliance and on the oven door frame...

Page 14: ...hould be connected to the ground terminal or wire lead on the range Connection at the connection block must be copper wire only U S Installation only 3 wire branch circuit Refer to figure where local...

Page 15: ...ppliance to the matching color wires in the junction box using UL CSA listed wire connectors Connect the white wire from the appliance to the neutral white wire in the junction box using a UL CSA list...

Page 16: ...ving the range The pressure regulator has 3 8 female pipe threads You will need to determine the fittings required depending on the dimension of your gas supply line the flexible metal connector and t...

Page 17: ...king in particular after prolonged use you are recommended to open a window or to increase the speed of any fans Gas connection Connect the adapter C ISO 228 1 NPT to the gas inlet of the appliance A...

Page 18: ...f the gas valve controls and adjust the connections Then check the connections again Remove all the detergent product from the range Replace the parts on the burner and turn the knobs on the gas tap v...

Page 19: ...to 4 W C P Incoming line pressure of 5 10 1 2 W C P maximum LP Gas Set pressure to 11 W C P Incoming line pressure 12 13 W C P maximum Lubricating the surface burner gas valves Over time the surface b...

Page 20: ...n the appliance 1 Unscrew the 2 nuts on the back of the worktop 2 Position the backguard A above the worktop 3 Secure the backguard to the worktop by tightening the screws B The handrail provided is a...

Page 21: ...You risk damage to this part of the appliance which may void the manufacturer s warranty Before leaving check all connections for gas leaks with soap and water DO NOT use a naked flame for detecting l...

Page 22: ...PAGE INTENTIONALLY LEFT BLANK...

Reviews: