Installation
19
EN
5.3 Section cut from the work surface
Create an opening with the dimensions
shown in the figure in the work surface of
the piece of furniture.
C
: 70 cm models with central UR.
L
: 70 cm models with side UR
Overall dimensions: gas and electrical
connection location (measures in mm)
60 cm models:
View from the bottom
G
Gas connection
E
Electrical connection
Rear view
Right view
The following operation requires
building and/or carpentry work
and must therefore be carried out
by a competent tradesman.
Installation can be carried out on
various materials such as masonry,
metal, solid wood or plastic
laminated wood as long as they
are heat resistant (
>90°C
).
L (cm)
X (mm)
Y (mm)
60 - 70
C
555 - 560
478 - 482
70
L
655 - 660
478÷ 482