Installation
49
EN
Burner and nozzle characteristics tables
Nozzles which are not provided are available at Authorised Service Centres.
1
Natural Gas G20
AUX
SR
RR
R1
R2
Rated heating capacity (kW)
1.1
1.7
2.6
3.5
3.0
Nozzle diameter (1/100 mm)
76
95
117
135
126
Reduced capacity (W)
400
500
750
1050
1050
Primary air (mm)
1.0
1.0
1.0
1.5
1.5
2
Natural Gas G25
AUX
SR
RR
R1
R2
Rated heating capacity (kW)
1.1
1.7
2.6
3.5
3.0
Nozzle diameter (1/100 mm)
76
95
117
135
126
Reduced capacity (W)
400
500
750
1050
1050
Primary air (mm)
1.0
1.0
1.0
1.5
1.5
3
Natural Gas G25
AUX
SR
RR
R1
R2
Rated heating capacity (kW)
1.1
1.7
2.6
3.5
3.0
Nozzle diameter (1/100 mm)
82
105
126
150
135
Reduced capacity (W)
400
500
750
1050
1050
Primary air (mm)
1.0
1.0
1.0
1.5
1.5
4
LPG G30/31
AUX
SR
RR
R1
R2
Rated heating capacity (kW)
1.1
1.7
2.6
3.4
3.0
Nozzle diameter (1/100 mm)
48
62
76
87
82
Reduced capacity (W)
400
500
750
1050
1050
Primary air (mm)
4
2
2
10
3
Rated capacity G30 (g/h)
80
124
189
247
218
Rated capacity G31 (g/h)
79
121
186
243
214
5
LPG G30/31
AUX
SR
RR
R1
R2
Rated heating capacity (kW)
1.1
1.7
2.6
3.5
3.0
Nozzle diameter (1/100 mm)
42
54
67
76
73
Reduced capacity (W)
450
550
850
1050
1050
Primary air (mm)
2
1
0.5
1.5
1.5
Rated capacity G30 (g/h)
80
131
189
254
218
Rated capacity G31 (g/h)
79
129
186
250
214
6
City Gas G110
AUX
SR
RR
R1
R2
Rated heating capacity (kW)
1.1
1.7
2.6
3.5
2.9
Nozzle diameter (1/100 mm)
132
165
230
280
250
Reduced capacity (W)
400
500
750
1050
1050
Primary air (mm)
1.0
0.5
1
1
1
7
City Gas G120
AUX
SR
RR
R1
R2
Rated heating capacity (kW)
1.1
1.7
2.6
3.5
3.0
Nozzle diameter (1/100 mm)
126
160
210
250
230
Reduced capacity (W)
400
500
750
1050
1050
Primary air (mm)
1
0.5
1
1
1