background image

 

 

Instructions for the user

 

 

34

 

7.

 

USING THE  HOB 

 

 

 

 

 

Before turning on the burners, make sure that the burner rings, caps and 
grids have been fitted correctly. 
In the ultrarapid burner, notch 

A

 must be aligned with pin 

B

Grid 

C

 provided is intended for use with woks (Chinese pans). 

Adapter 

D

 comes only with open grids models and is intended for use 

with small sized vessels. 

 

 

 

 

 

 

7.1

 

Ignition of the burners 

 

Raised indicators make for easier and clearer reading and use of the 
controls, each knob being connected to its corresponding burner by a 
rib. Setting corresponds to the elongated part of the knob or to the 
marking on it. 

 

(Only where applicable) 
Double-

crown

 burners, controlled by two knobs, feature two ribs, a long 

one corresponding to the small inner burner and a short one to the outer 
burner. 
Double-

crown

 burners comprise an auxiliary and a rapid burner, 

controlled by two different knobs which permit to use both burners at the 
same time or to select one or the other as required. 

 

 

 

 

The device is fit with electronic ignition. Simply press and simultaneously 
turn the knob counter-clockwise on the low point flame symbol, until the 
burner is ignited. Concerning models with valves, push the knob for 
approximately 2 seconds in order to keep the flame burning and to 
activate the safety device. The burner might go off when the knob is 
released. In this case repeat the aforesaid operation keeping the knob 
pressed for more than 2 seconds. 

 

 

 

 

Should the burners go off accidentally in the models with valves, a safety 
device will trip after approximately 20 seconds to block the gas outlet 
even if the tap is open. 

 

 

Summary of Contents for GKCO64-3

Page 1: ..._______________________________________ 34 8 CLEANING AND MAINTENANCE ___________________________ 37 THESE INSTRUCTIONS ARE VALID ONLY FOR END USER COUNTRIES WHOSE IDENTIFICATION SYMBOLS APPEAR ON THE...

Page 2: ...DECLINES ALL RESPONSIBILITY FOR IMPROPER USE DO NOT LEAVE THE PACKING IN THE HOME ENVIRONMENT SEPARATE THE VARIOUS WASTE MATERIALS AND TAKE THEM TO THE NEAREST SPECIAL GARBAGE COLLECTION CENTRE IT IS...

Page 3: ...LE PLATES THAT EXTEND BEYOND THE EXTERNAL PERIMETER OF THE HOB THE HOB IS TO BE USED BY ADULTS ONLY DO NOT LET UNSUPERVISED CHILDREN PLAY WITH THE HOB THIS APPLIANCE IS MARKED ACCORDING TO THE EUROPEA...

Page 4: ...mounted against walls higher than the work surface on condition that a certain distance X be kept between the appliance and the wall as shown in the figure so as to avoid damage from overheating Make...

Page 5: ...anel has to be placed under the hob Keep a minimum distance of 10 mm between the bottom of the unit and the panel surface The panel has to be easily removable to allow access in the event of technical...

Page 6: ...accessible position near the unit Do not use reducers adapters or shunts If the power cable is replaced the wire section on the new cable must not be less than 1 5 mm 2 3 x 1 5 cable keeping in mind...

Page 7: ...been inspected for G25 2L 3B P at a pressure of 25 mbar For use with other types of gases see Section 5 ADAPTATION TO DIFFERENT TYPES OF GAS The gas intake fitting is gas external threaded ISO 228 1 C...

Page 8: ...intakes protected by screens must be appropriately sized regulations in force and placed so as not to be blocked in any way The room where the oven is installed should be suitably ventilated to avoid...

Page 9: ...placed and the primary air adjusted To replace the nozzles and regulate the burners you have to remove the top as described in the following paragraph 5 1 Removing the hob 1 Remove all the knobs the g...

Page 10: ...ndicated in the chart in paragraph 5 4 Regulation of primary air and then secure the tube by means of screw A After the regulations have been carried out restore the seals with sealing wax or equivale...

Page 11: ...out restore the seals with sealing wax or equivalent material Burner Rated heating capacity kW G25 25 mbar Nozzle diameter 1 100 mm Reduced flowrate W Auxiliary 1 1 05 76 380 Semi rapid 2 1 65 98 380...

Page 12: ...he model until you get a suitable minimum flame Replace the knob and check burner flame stability rapidly turning the knob from maximum to minimum position the flame should not go out 6 2 Regulation o...

Page 13: ...1 Auxiliary 2 Semi rapid 3 Rapid 4 Ultra rapid 5 Double crown 6 Fish pan 7 Ultra rapid 6 4 Lubrication of gas taps After a while the gas tap may become hard to turn or lock If this happens it has to b...

Page 14: ...long one corresponding to the small inner burner and a short one to the outer burner Double crown burners comprise an auxiliary and a rapid burner controlled by two different knobs which permit to us...

Page 15: ...ference numbers see page 33 7 4 Using a griddle plate A few precautions are necessary if you wish to use a griddle plate leave a gap of at least 160 mm between the edge of the griddle plate and the si...

Page 16: ...ing point to 4 Medium roast delicate meat or fish 5 Strong For roasts steaks and large boiled joints 3 6 Very strong To boil large amounts of water to fry WARNING When switching on the electric elemen...

Page 17: ...the surface always use specific products only which do not contain abrasive substances or chlorine based acid substances How to use pour the product on a damp cloth and wipe the surface rinse thoroug...

Page 18: ...l products for appliance cleaning and care 8 2 1 Ignition plugs and safety devices For good functioning of the lighting ignition plugs and the safety devices keep them very clean Check frequently and...