![Smeg Classica Aesthetic SX91GM Manual Download Page 22](http://html1.mh-extra.com/html/smeg/classica-aesthetic-sx91gm/classica-aesthetic-sx91gm_manual_1301470022.webp)
52 - INSTALLATION
91477A593/C
spindle clockwise all the way.
Lubricating the gas cocks
Over time the gas cocks may become difficult to
turn and get blocked. Clean them internally and
replace the lubrication grease.
Gas types and Countries
It is possible to identify the available gas types based on the country the appliance is to be installed
in. Refer to the heading number to identify the correct values in the “Burner and nozzle characteristics
tables".
Burner and nozzle characteristics tables
Following adjustment to a gas other
than the one originally set in the factory,
replace the gas setting label on the
appliance with the one corresponding
to the new gas. The label is inserted
inside the nozzle pack (where present).
Lubrication of the gas cocks should be
performed by a specialised technician.
Gas types
IT
GB
IE
FR
BE
ES
PT
RU
SE
DK
FI
NO
PL
HU
1 Natural Gas G20
G20
20 mbar
•
•
•
•
•
•
•
•
G20/25
20/25 mbar
•
2 Natural Gas G20
G20
25 mbar
•
3 Natural Gas G25.1
G25.1
25 mbar
•
4 Natural Gas G2.350
G2.350
13 mbar
•
5 LPG G30/31
G30/31
28-30/37 mbar
•
•
•
•
•
•
G30/31
30/30 mbar
•
•
•
6 LPG G30/31
G30/31
37 mbar
•
7 Town Gas G110
G110
8 mbar
•
•
1 Natural Gas G20 - 20 mbar
AUX
SR
R
UR2
Rated heating capacity (kW)
1.0
1.8
2.9
4.0
Nozzle diameter (1/100 mm)
72
94
115
145
Pre-chamber (printed on nozzle)
(X)
(Y)
(Y)
/13
Reduced flow rate (W)
400
500
800
1400
2 Natural Gas G20 - 25 mbar
AUX
SR
R
UR2
Rated heating capacity (kW)
1.1
1.8
2.9
4.2
Nozzle diameter (1/100 mm)
72
94
110
135
Pre-chamber (printed on nozzle)
(X)
(Z)
(H8)
(S)
Reduced flow rate (W)
400
500
800
1600
3 Natural Gas G25.1 - 25 mbar
AUX
SR
R
UR2
Rated heating capacity (kW)
1.0
1.8
2.9
4.0
Nozzle diameter (1/100 mm)
77
100
134
152
Pre-chamber (printed on nozzle)
(F1)
(Y)
(F3)
(F3)
Reduced flow rate (W)
400
500
800
1600