Installation
83
EN
The nozzles not provided are available at Authorised Service Centres.
8 LPG G30/31
AUX
SR
UR-3c
Rated heating capacity (kW)
1.05
1.8
3.9
Nozzle diameter (1/100 mm)
50
65
100
Pre-chamber (printed on nozzle)
-
-
-
Reduced flow rate (W)
400
500
1600
Rated flow rate G30 (g/h)
76
131
284
Rated flow rate G31 (g/h)
75
129
279
9 LPG G30/31
AUX
SR
UR-3c
Rated heating capacity (kW)
1.1
1.8
3.9
Nozzle diameter (1/100 mm)
50
65
94
Pre-chamber (printed on nozzle)
-
-
-
Reduced flow rate (W)
450
550
1600
Rated flow rate G30 (g/h)
80
131
284
Rated flow rate G31 (g/h)
79
129
279
10 LPG G30/31
AUX
SR
UR-3c
Rated heating capacity (kW)
1.05
1.8
3.9
Nozzle diameter (1/100 mm)
43
58
77
Pre-chamber (printed on nozzle)
(H2)
(M)
(F4)
Reduced flow rate (W)
400
500
1600
Rated flow rate G30 (g/h)
76
131
284
Rated flow rate G31 (g/h)
75
129
279
11 Town Gas G110
AUX
SR
UR-3c
Rated heating capacity (kW)
1.05
1.8
3.9
Nozzle diameter (1/100 mm)
145
185
340
Pre-chamber (printed on nozzle)
8
2
13
Reduced flow rate (W)
400
500
1200
12 Town Gas G120
AUX
SR
UR-3c
Rated heating capacity (kW)
1.05
1.8
3.9
Nozzle diameter (1/100 mm)
135
175
315
Pre-chamber (printed on nozzle)
8
2
13
Reduced flow rate (W)
400
500
1400