Burner and nozzle specifications tables
The nozzles not provided are available at Authorised Service Centres.
Natural gas G20 – 20 mbar
AUX
SR
UR
Rated heating capacity (kW)
1.05
1.8
3.9
Nozzle diameter (1/100 mm)
72
97
135
Pre-chamber (printed on nozzle)
(X)
(Z)
(S)
Reduced flow rate (W)
400
500
1600
LPG G30/31 – 30/37 mbar
AUX
SR
UR
Rated heating capacity (kW)
1.05
1.8
3.9
Nozzle diameter (1/100 mm)
50
65
100
Pre-chamber (printed on nozzle)
-
-
-
Reduced flow rate (W)
400
500
1600
Rated flow rate G30 (g/h)
76
131
284
Rated flow rate G31 (g/h)
75
129
279
Town gas G110 – 8 mbar
AUX
SR
UR
Rated heating capacity (kW)
1.05
1.8
3.9
Nozzle diameter (1/100 mm)
145
185
340
Pre-chamber (printed on nozzle)
/8
/2
/13
Reduced flow rate (W)
400
500
1200
Town gas G120 – 8 mbar
AUX
SR
UR
Rated heating capacity (kW)
1.05
1.8
3.9
Nozzle diameter (1/100 mm)
135
175
315
Pre-chamber (printed on nozzle)
/8
/2
/13
Reduced flow rate (W)
400
500
1400