-5-
1. How to Operate
1.1 Outline
1. This is equipment used to remove dust that is stuck to a workpiece due to static and to remove static
electricity and collect dust to prevent dust from sticking to the workpiece again.
2. Ionized air from IZN10E ionizer neutralizes static electricity and blows dust away from the workpiece.
1.2 Installation and Piping
1. This product must be installed on a stable horizontal surface.
2. Avoid using in a place where noise (electromagnetic wave and surge) is generated.
It may cause failure or damage to the product. Take measures to prevent noise at source and avoid
power and signal lines from coming into close contact.
3. Do not allow foreign matter, workpiece or tool to enter the ionizer nozzle.
There is an emitter inside the nozzle. If the emitter gets in contact with metallic workpieces or tools,
electrical shock may cause injury. If emitter is damaged, it may interfere with the specified function and
performance, and may also cause operation failure and accident.
4. Mounting, wiring or adjustments should never be done without shutting off the power supply to the
product.
5. Make sure to confirm the effect of static elimination after installation.
6. Power supply required to the product is 24 VDC and 1A.
When power is supplied to the product without using the exclusive AC adapter, make sure to use a
stabilization power supply and connect wiring to the DC plug that is provided with the product as an
accessory.
- Refer to P6 for wiring.
7. AC power supply cable of the exclusive AC adapter has a socket configuration that is for 100 VAC.
The AC adapter is applicable to 100 to 240V. Replace it with a socket that is applicable to other voltage if
necessary. The socket needs to be prepared by the user.
8. D-class ground connection (ground with a resistance of less
than 100Ω) MUST be used to the product.
Without grounding, the product will not provide the designed performance.
9. Operate in an environement in the specified ambient temperature and fluid temperature ranges
(0 to 55
o
C).
Avoid sudden temperature changes even within specified temperature range, as it may cause
condensation.
10. For air piping, use SMC tubing of diameter 10 mm or equivalent.
11.
It is recommended to use supply air which purity class is 2:4:3
2:5:3
2:6:3 of ISO08573-1:2010
(
JIS
B8392-1:2012
)
or higher. The air containing mist or dust will cause the performance to decrease and
shorten the maintenance cycle. Install a dryer (IDF series), air filter (AF/AFF series), and/or mist
separator (AFM/AM series) to the upstream of the product to obtain clean compressed air.
12. Air connections should only be made with the pressure supply turned off.
Flush the system before piping to prevent foreign matter from entering inside the product.
13. Do not allow humans or objects to touch the ionizer while power is being supplied.
Otherwise, the offset voltage may change or the HV LED may turn ON.
14. Do not make a rapid pressure change while power is being supplied to the ionizer.
It will cause the NDL LED to turn ON.
15. Do not use this product in an enclosed space.
This product utilizes the corona discharge phenomenon. Although the amount is very small, Ozone and
NOx are generated. Ozone condensation can increase if used in an enclosed space, which can affect
the human body, so ventilation is necessary. Even when the room is ventilated, operating more than one
product in a small space may increase the ozone density. Confirm that
the ozone density in the operating environment is not more
than the standard value of 0.1 ppm before starting operation.
16. When the dust collector is operating, air is discharged
vigorously from the exhaust port.
Prevent exhausted air from contacting people or objects.
Piping (I.D. 32mm) or dust collecting bag must be connected
to the exhaust port.
17. Read and understand the Operation Manual of this product
before using. Confirm safety before starting operation.
18. If anything such as a part drops through to the bottom in the
static elimination area, remove the mesh and take it away.
*
Mesh is
removable