2.5 Offset Voltage and Discharge Time
Actual measurement values of the static elimination performance at the points 1 to 6 are shown below.
(See Notes shown below)
- Continuous operation of the additional air flow
- Pulse operation of the additional air flow(50ms)
Point for
measure
ment
Offset voltage (V)
Discharge
time (s)
Point for
measure
ment
Offset voltage(V)
Discharge
time (s)
(1)
1.9
0.20
(1)
0.6
0.20
(2)
1.3
0.22
(2)
2.5
0.20
(3)
0.6
0.21
(3)
1.3
0.20
(4)
1.9
0.35
(4)
1.3
0.36
(5)
1.9
0.41
(5)
1.9
0.37
(6)
3.1
0.40
(6)
3.1
0.39
- Pulse operation of the additional air flow (100 ms)
- Without operation of the additional air flow
Point for
measure
ment
Offset voltage (V)
Discharge
time (s)
Point for
measure
ment
Offset voltage(V)
Discharge
time (s)
(1)
0.0
0.19
(1)
-0.6
0.18
(2)
0.6
0.19
(2)
0.0
0.18
(3)
1.3
0.19
(3)
0.0
0.18
(4)
0.6
0.37
(4)
0.0
0.40
(5)
1.3
0.39
(5)
0.6
0.50
(6)
2.5
0.37
(6)
1.3
0.45
Notes:
- When additional air flow pressure is set to 0.2MPa and supply pressure to the dust collector to
0.4MPa.
- Discharge time is the time required to reduce electricity on the static plate (150 mm x 150 mm, static
capacity 20 pF) from 1000 V to 100 V.
- The above shown values are measured using SMC's measurement instruments and conditions, and not
the guaranteed values.
3. Ionizer Functions
100
230
①
②
③
④
⑤
⑥
400
イオナイザ
90
90
Ionizer