background image

 

ZL112-TFK33GB

 

 

Installation and Maintenance Manual 

Multistage Ejector 

ZL112 Series

 

 
 

1 Safety Instructions 

This manual contains  essential  information for the  protection  of  users  and 
others from possible injury and/or equipment damage. 

  Read  this  manual  before  using  the  product,  to  ensure  correct  handling, 

and read the manuals of related apparatus before use. 

  Keep this manual in a safe place for future reference. 

  These  instructions  indicate  the  level  of  potential  hazard  by  label  of 

“Caution”,  “Warning”  or  “Danger”,  followed  by  important  safety 
information which must be carefully followed. 

  To  ensure  safety  of  personnel  and  equipment  the  safety  instructions  in 

this  manual  and  the  product  catalogue  must  be  observed,  along  with 
other relevant safety practices. 

 

 

 

Caution 

Indicates a hazard with a low level of risk, which if not 
avoided, could result in minor or moderate injury. 

 

 

Warning 

Indicates a hazard with a medium level of risk, which 
if not avoided, could result in death or serious injury. 

 

 

Danger 

Indicates a hazard with a high level of risk, which if 
not avoided, will result in death or serious injury. 

 
 
 
 
 
 

Warning 

  The  compatibility  of  pneumatic  equipment  is  the  responsibility  of  the 

person who designs the pneumatic system or decides its specifications. 
Since  the  products  specified  here  can  be  used  in  various  operating 
conditions,  their  compatibility  with  the  specific  pneumatic  system  must 
be based on specifications or after analysis and/or tests to meet specific 
requirements. 

 

Only  trained  personnel  should  operate  pneumatically  operated 
machinery and equipment. 

Compressed  air  can  be  dangerous  if  an  operator  is  unfamiliar  with  it. 
Assembly, handling or repair of pneumatic systems should be performed 
by trained and experienced personnel. 

 

Do  not  service  machinery/equipment  or  attempt  to  remove 
components until safety is confirmed. 

1)  Inspection  and  maintenance  of  machinery/equipment  should  only  be 
performed after confirmation of safe locked-out control positions. 
2)  When  equipment  is  to  be  removed,  confirm  the  safety  process  as 
mentioned  above.  Switch  off  air  and  electrical  supplies  and  exhaust  all 
residual compressed air in the system. 
3) Before machinery/equipment is re-started, ensure all safety measures 
to prevent sudden movement of cylinders etc. (Supply air into the system 
gradually to create back pressure, i.e. incorporate a soft-start valve). 

 

Do not use this product outside of the specifications. Contact SMC 
if it is to be used in any of the following conditions: 

1) Conditions and environments beyond the given specifications, or if the 
product is to be used outdoors. 
2) Installations in conjunction with atomic energy, railway, air navigation, 
vehicles, medical equipment, food and beverage, recreation equipment, 
emergency stop circuits, press applications, or safety equipment. 
3) An application which has the possibility of having negative effects on 
people, property, or animals, requiring special safety analysis.  

 

Caution 

  Ensure that the air supply system is filtered to 5 microns. 

 

2 Specifications 

2.1  Specifications 

Specification of ejector 

Model 

ZL112 

ZL112-G 

ZL112-Dx-Q 

ZL112-

K1/K2x-x-Q 

Nozzle diameter 

φ

1.2mm 

Max. suction flow rate 

100 l/min (ANR) 

Air consumption 

63 l/min (ANR) 

Max. vacuum pressure 

-84kPa 

Max. operating pressure 

0.7Mpa 

Supply pressure range 

0.2 to 0.5Mpa 

Standard supply pressure 

0.4Mpa 

Operating temperature range 

5 to 50°C 

Option 

No option 

(Standard) 

With vacuum 

pressure 

gauge 

With vacuum 

pressure 

switch 

With valve 

Enclosure 

Equivalent to IP30 

 

Valve specifications (SYJ500 series) 

Fluid 

Air 

Operating pressure 
range 

Internal pilot 
type 

0.15 to 0.7MPa 

Ambient and fluid temperature 

-10~50°C (No freezing.) 

Response time (at 0.5MPa) 

25 ms or less 

Max. operating frequency 

5 Hz 

Effective sectional area 

0.25 Cv 

Manual override (Manual operation) 

Non-locking push type 

Lock driver operation type, Lock manual operation type 

Pilot exhaust method 

Pilot valve separate exhaust, Main valve, Pilot valve 

common exhaust 

Lubrication 

Not required 

Mounting orientation 

Unrestricted 

Shock  / Vibration resistance 

150/30 m/s² 

Enclosure 

Dust proof 

 

Digital vacuum pressure switch specifications (ZSE30A type) 

Rated pressure range 

0.0 to -101.0kPa 

Set pressure range 

10.0 to -105.0kPa 

Proof pressure 

500kPa 

Min. display unit 

0.1kPa 

Applicable fluid 

Air, inert gas, Non-flammable gas 

Power supply voltage 

12 to 24VDC

±

10%,Ripple(p-p)10% or less 

(With power supply polarity protection)  

Current consumption  

40mA or less 

Switch output 

NPN or PNP open collector 1 output 

NPN or PNP open collector 2 output (selectable) 

 

Max. load current 

80mA 

 

Max. applied voltage 

28V (With NPN output) 

 

Residual voltage 

1V or less (With load current of 80mA) 

 

Response time 

2.5ms or less 

(Response time selections with anti-chattering function: 

20, 100, 500, 1000, 2000ms) 

 

Output protection 

Short  circuit protection 

Repeatability 

±

0.2%F.S. 

±

1digit 

Hysteresis mode 

Hysteresis 

Window comparator 
mode 

Adjustable (can be set from 0) (note) 

Output voltage 

1 to 5v

±

2.5%F.S. 

Linearity 

±

1%F.S. or less 

V

o

lt

a

g

e

  

o

u

tp

u

t

 

Output impedance 

Approx. 1k

Ω

 

Output current 

4 to 20mA

±

2.5%F.S. 

Linearity 

±

1%F.S. or less 

A

n

a

lo

g

u

e

 o

u

tp

u

C

u

rr

e

n

o

u

tp

u

Load impedance 

Max. load impedance: 

300

Ω

 with power supply voltage of 12V 

600

Ω

 with power supply voltage of 24V 

Min. lad  impedance:50

Ω

 

Display method 

4-digit 7-segment indicator LCD 2-color display 

(Red and green) 

Indicator accuracy 

±

2%F.S.

±

1digit(at 25

℃±

3

 ambient temperature) 

Indicator 

LED lit when output is ON OUT1: Green OUT2 :Red 

Enclosure 

IP40 

Ambient temperature 

Operating:0 to 50

,Stored: -10 to 60

 

(No freezing or condensation) 

Ambient  humidity 

Operating and stored: 35 to 85%RH(No condensation) 

Withstand voltage 

1000VAC for1 min, between live parts and enclosure 

Insulation resistance 

50M

Ω

 or more between live parts and enclosure 

(at 500VDC) 

Vibration proof 

10 to 150Hz 1.5mm or20m/s

2

 amplitude in X,Y,Z directions 

for 2 hours each 

E

n

vi

ro

n

m

e

n

ta

R

e

si

st

a

n

ce

 

Impact resistance 

100m/s

2

 

X,Y,Z directions3 times each 

Temperature characteristics 

±

2%F.S.(based on 25

Lead wire 

Oil resistant heavy-duty vinyl cable 3 wire 

φ

3.5 2m 

4 wire conductor cross section: 0.15mm

2

(AWG26) 

Insulator outside diameter: 1.0mm  

Note) If the applied voltage fluctuates around the set value, the set hysteresis must exceed the 
fluctuation width, otherwise, chattering will occur. 

 

Vacuum pressure gauge specification 

Model No. 

GZ30S 

Fluid 

Air 

Pressure range 

-100 to 100kPa 

Scale angle 

230

°

 

Accuracy 

±

3% F. S. (full span) 

Class 

Class 3 

Operating temperature range 

0 to 50°C 

Material 

Case: Polycarbonate / ABS resin 

 

2.2  Circuit Symbols 

 

 

 
 

 

 
 
 
 

 

 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

3 Installation 

3.1  Installation 

Warning 

  Do not install the product unless the safety instructions have been read 

and understood 

 
 
 

3.2  Environment 

Warning 

  Do  not  use  in  an  environment  where  corrosive  gases,  chemicals,  salt 

water or steam are present. 

  Do not use in an explosive atmosphere. 

  Do not expose to direct sunlight. Use a suitable protective cover. 

  Do  not  install  in  a  location  subject  to  vibration  or  impact.  Check  the 

product specifications. 

  Do not mount in a location exposed to radiant heat. 

 

3.3  Piping 

Warning 

  Before piping make sure to clean up chips, cutting oil, dust etc. 

  When installing piping or fittings, ensure sealant material does not enter 

inside the port. When using seal tape, leave 1.5 to 2 threads exposed on 
the end of the pipe/fitting.  

  Tighten fittings to the specified tightening torque. 

 

Thread 

Tightening Torque 

M5 

By hand + 1/6 turn with a wrench (1/4 turn for miniature fittings) 

Rc 1/8 

7 to 9 

 

 
 
 
 
 
 
 
 
 
 
 

 

3.4  Electrical Connection 

Caution 

  When  DC  power  is  connected  to  a  solenoid  valve  equipped  with  light 

and/or surge voltage suppressor, check for polarity indications. 

  For polarity indications: 

 

No  diode  to  protect  polarity:  if  polarity  connection  is  wrong,  the 
diode  in  the  valve  or  switching  device  at  control  equipment  or 
power supply may be damaged. 

 

With  diode  to  protect  polarity:  if  polarity  connection  is  wrong,  the 
valve does not switch.

 

 

Vacuum Pressure Switch Wiring Diagram (ZSE30A type) 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
 
 
 
 
 
 
 

 

Wiring electronic Pressure Switch 

 

Confirm wire colours and terminal numbers when wiring. 

Since  incorrect  wiring  can  lead  to  breakage  or  failure  of  the  switch  as 
well  as  malfunction,  perform  wiring  after  confirming  wiring  colours  and 
terminal numbers with the instruction manual. 

 

Avoid repeatedly bending or stretching lead wires. 

Broken  lead  wires  will  result  from  applying  bending  stress  or  stretching 
force  to  the  lead  wires.  In  the  event  that  lead  wires  are  damaged 
creating  a  possibility  of  malfunction,  replace  the  entire  product.  (For 
cases in which the lead wires cannot be replaced through grommets.) 

 

Confirm proper insulation of wiring. 

Be  certain  that  there  is  no  faulty  wiring  insulation  (contact  with  other 
circuits,  ground  fault,  improper  insulation  between  terminals,  etc.). 
Damage may occur due to excess current flow into a switch. 

 

Do not wire with power lines or high voltage lines. 

Wire separately from power lines or high voltage lines, avoiding parallel 
wiring or wiring in the same conduit.  Control circuits containing switches 
may malfunction due to noise from other lines. 

 

Do not allow short circuiting of loads. 

Use caution, as switches will be damaged if a load is short circuited.  Be 
especially  careful  not  to  reverse  the  power  supply  line  (Brown)  and  the 
output line (Black).

 

 

Pressure supply port 
 

Vacuum port

 

Vacuum port

Without valve 

With valve 

K1 type

 

K2 type 

With valve 

Output specification: N 

Output specification: P 

Output specification: A 

Output specification: B 

Output specification: C 

Output specification: D 

Output specification: E 

Output specification: F 

Reviews: