SMC Networks ZFC Series Operation Manual Download Page 1

No.FGX-OM-Q013-A 

 

 

 

 

 

 

 

 
 

PRODUCT NAME 

 

In-line Air Filter   

 

MODEL / Series / Product Number 

 

Series ZFC

 

ZFC1

-

∗ 

ZFC3

-

 

ZFC5

-

 

ZFC7

-

 

 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for ZFC Series

Page 1: ...No FGX OM Q013 A PRODUCT NAME In line Air Filter MODEL Series Product Number Series ZFC ZFC1 ZFC3 ZFC5 ZFC7...

Page 2: ...1 Contents Safety Instructions P 2 Series ZFC specific product precautions P 4 1 Product components and functions P 6 2 Specifications P 7 3 Mounting P 11 4 Element Replacement P 12...

Page 3: ...of equipment failure when configuring the equipment 2 Only personnel with appropriate training should operate machinery and equipment The product specified here may become unsafe if handled incorrect...

Page 4: ...r responsibility a replacement product or necessary parts will be provided This limited warranty applies only to our product independently and not to any other damage incurred due to the failure of th...

Page 5: ...to drain option is recommended Refer to SMC Air Preparation System for further details on compressed air quality 4 Use clean air Do not use compressed air that contains chemicals synthetic oils that i...

Page 6: ...lter should be prepared It is not possible to use vacuum pressure and positive pressure together on the same line 6 When the element becomes clogged stop operation and adjust the internal pressure of...

Page 7: ...ect the IN side tube The cover can be removed when replacing the element 4 Cover OUT side PBT Used to connect the OUT side tube The cover cannot be removed 5 Cassette Tube can be removed mounted or he...

Page 8: ...ion area 1 5 L min 140 mm 2 3 10 L min 470 mm 2 5 20 L min 750 mm 2 7 100 L min 1260 mm 2 Applicable tubing O D Metric size Symbol Applicable tubing O D ZFC1 ZFC3 ZFC5 ZFC7 1 2 2 3 2 3 4 4 6 5 8 6 10...

Page 9: ...pressure Operating temperature range 0 to 60 o C No freezing Filtration 5 m Filtration efficiency 95 Element replacement differential pressure With positive pressure 0 1 MPa Even though the pressure...

Page 10: ...9 2 3 Dimensions 1 ZFC1 2 ZFC3 3 ZFC5 Applicable tubing O D 2 3 2 1 8 Applicable tubing O D 3 2 4 1 8 5 32 Applicable tubing O D 4 6 5 32 1 4...

Page 11: ...10 4 ZFC7 Applicable tubing O D 10 12 3 8 Applicable tubing O D 6 8 1 4 5 16...

Page 12: ...oving the cover IN side Note Refer to One touch Fittings Precautions for mounting and removal of the tube 2 Operation Be sure to check that the lock mechanism is locked to prevent the cover IN side fr...

Page 13: ...t Replacement Procedure 1 Stop the operation and release the pressure in the filter to the atmospheric pressure return the vacuum pressure to the atmospheric pressure 2 Slide the lock mechanism in the...

Page 14: ...1 Sotokanda Chiyoda ku Tokyo 101 0021 JAPAN Tel 81 3 5207 8249 Fax 81 3 5298 5362 URL http www smcworld com Note Specifications are subject to change without prior notice and any obligation on the pa...