background image

IP65

Enclosure

 Electrical entry

   “Faston” type
     terminal is IP40.

 

 

  

2 Port Solenoid Valve/Air Operated Valve 
For Dust Collector

Flange type

Flange body type

Flange body 

I

 type 

(Flange mounting type)

Mounting can be changed 
according to the piping 
conditions.

Flange body type

Orifice machining on the outlet is not required 

so, installation time is reduced!

Direct piping type

Faston terminal

type added 

Port size

50A to 100A

added

Flange type, 

Flange body type 

added 

Large port

sizes available.

Piping

Power

consumption

4.5

 W

 Excluding size 23

Solenoid 
valve type

Air operated type

Flange body 

II

 type 

(Through hole mounting type)

RoHS

Installation Example

Flange type

Direct

piping

type

20A

25A

40A

50A

65A

80A

90A

100A

Flange

type

Flange body 

I

 type

Flange body

II

 type

Port size

Type

Piping

Solenoid valve  type

Air operated type

Grommet

DIN terminal

Conduit terminal

Conduit

Faston terminal

Variations

Electrical entry

 Solenoid valve type only

New

New

New

New

New

New

New

New

New

New

Flange mounting

type

Through hole

mounting type

CAT.EUS70-47A-UK

New

New

Series 

VXF2/VXFA2

Summary of Contents for VXF2 Series

Page 1: ...Flange body type added Large port sizes available Piping Power consumption 4 5 W Excluding size 23 Solenoid valve type Air operated type Flange body II type Through hole mounting type RoHS Installati...

Page 2: ...21 22 24 25 26 27 28 8W Size 23 Built in full wave rectifier type AC specification Built in full wave rectifier type AC specification Improved durability Service life is extended by special construct...

Page 3: ...ascades Interrupting an operation from an external switch is possible using input signals Operation sequence diagram Operation sequence diagram Operation sequence diagram Connection 4 outpus Dual puls...

Page 4: ...g to 60 5 to 60 Class B IP65 10 of rated voltage 7 4 5 7 4 5 10 8 44 53 VXF25 A B VXF26 A B C D VXF27B VXF28B 70 80 90 100 3 4 1 1 1 2 2 2 1 2 3 3 1 2 4 Specifications Solenoid Coil Specifications Siz...

Page 5: ...48 VAC 220 VAC 240 VAC 24 VAC 12 VDC 24 VDC 100 VAC 110 VAC 200 VAC 230 VAC 48 VAC 220 VAC 240 VAC 24 VAC 12 VDC 24 VDC 100 VAC 110 VAC 200 VAC 230 VAC 48 VAC 220 VAC 240 VAC 24 VAC 12 VDC 24 VDC 100...

Page 6: ...OM With silencer Symbol A B e Diaphragm Main valve material Select whether a silencer is required Step 4 Specifications Air Operated Type VXFA21AA VXFA22AA VXFA23AA VXFA24A A B Orifice size mm Port si...

Page 7: ...phragm Main valve material Without With With without silencer Air Operated Type A Direct piping type B Flange type C Flange body I type Flange mounting type D Flange body II type Through hole mounting...

Page 8: ...izing time 150 msec Rated voltage 24 VDC Outlet piping length 500 mm Thread size of outlet piping VXF21 Rc3 8 VXF22 Rc1 2 VXF23 Rc3 4 VXF24 Rc1 VXF25 Rc1 1 2VXF26 Rc2 VXF27 Rc2 1 2VXF28 Rc3 How to cal...

Page 9: ...to the pilot valve mm Start up speed MPa msec 0 0 01 0 02 0 03 0 04 0 04 0 05 0 500 1000 1500 Piping length to the pilot valve mm Start up speed MPa msec 0 0 01 0 02 0 03 0 04 0 05 0 500 1000 1500 Pip...

Page 10: ...conditions Test circuit Refer to the circuit below Test sample VXFA21A Port size 3 4 VXFA22A Port size 1 VXFA23A Port size 1 1 2 VXFA24A Port size 2 VXFA25A B Port size 2 1 2 VXFA26A B C D Port size 3...

Page 11: ...ct piping type 4 5 6 VXFA2 A Direct piping type 4 5 6 t y r w q e VXF A 21AA B VXF A 22AA B VXF A 23AA B VXF A 24AA B VXF A 25AA B VXF A 26AA B Solenoid valve type VXF 21AA VXF 22AA VXF 23AA VXF 24AA...

Page 12: ...lange body II type VXF26C Flange body I type VXFA26C Flange body I type VXF A 25BA B VXF A 26BA B VXF A 26CA B VXF A 26DA B VXF A 27BA B VXF A 28BA B Solenoid valve type VXF 25AA VXF 26BA VXF 26CA VXF...

Page 13: ...154 5 G 40 47 77 H 53 5 64 5 95 I 29 5 29 5 32 J 68 5 68 5 71 K 39 39 39 L 16 5 16 5 16 5 S 30 30 35 F 19 23 5 35 mm VXF21A VXF22A VXF23A Model Q Grommet Grommet with surge voltage suppressor R U Q R...

Page 14: ...66 74 110 66 74 110 36 45 63 107 118 154 5 F 19 23 5 35 mm VXF21A VXF22A VXF23A G H I J K L 40 47 77 53 5 64 5 95 29 5 29 5 32 68 5 68 5 71 39 39 39 16 5 16 5 16 5 S 30 30 35 Model Q Conduit terminal...

Page 15: ...6 to 12 S Dimensions Model Port size P A B C D E 2 136 112 112 78 185 F 40 mm VXF24A G H I J K L 80 118 23 5 62 5 39 16 5 S 30 Model Q Grommet Grommet with surge voltage suppressor R U Q R U 27 20 17...

Page 16: ...12 5 11 Q R I 1 4 Exhaust port L S U Port size 2 P F Dimensions Model Port size P A B C D E 2 136 112 112 78 185 F 40 mm VXF24A G H I J K L 80 118 23 5 62 5 39 16 5 S 30 Model Q Conduit terminal Cond...

Page 17: ...2 1 2 3 182 206 92 102 212 247 47 63 117 5 119 H 141 176 mm VXF25A VXF26A I J K L S 18 6 18 6 78 4 78 4 59 8 59 8 24 24 30 30 Model Q Grommet Grommet with surge voltage suppressor R U Q R U 27 27 20 2...

Page 18: ...P Dimensions Model Port size P A D E F G 2 1 2 3 182 206 92 102 212 247 47 63 117 5 119 H 141 176 mm VXF25A VXF26A I J K L S 18 6 18 6 78 4 78 4 59 8 59 8 24 24 30 30 Model Q Conduit terminal Conduit...

Page 19: ...X 17 17 17 17 mm VXF25B VXF26B VXF27B VXF28B Y Z J K L S 18 3 34 34 34 90 100 110 120 78 4 78 4 78 4 78 4 59 8 59 8 59 8 59 8 24 24 24 24 30 30 30 30 Model Q Grommet Grommet with surge voltage suppres...

Page 20: ...21 47 50 50 50 18 6 18 6 18 6 18 6 X 17 17 17 17 mm VXF25B VXF26B VXF27B VXF28B Y Z J K L S 18 3 34 34 34 90 100 110 120 78 4 78 4 78 4 78 4 59 8 59 8 59 8 59 8 24 24 24 24 30 30 30 30 Model Q Conduit...

Page 21: ...0 2 80 or more 89 1 0 8 156 0 3 B R 2 R 1 7 x 45 2 2 5 178 0 2 8 x M10 x 1 5 x 20 C1 8 x M10 x 1 5 x 20 C1 178 0 2 90 or more 101 6 0 8 156 0 3 34 0 2 R 2 B R 1 R 1 90A Steel tube 7 x 4 5 2 2 5 100 or...

Page 22: ...J I R 247 247 S S S Note Refer to page 23 for the dimensions of the mounting interface 6 x M10 x 1 5 x 30 6 x M10 x 1 5 x 30 Dimensions Model E I J K S 169 18 6 78 4 59 8 30 mm VXF26C Q Grommet Gromme...

Page 23: ...10 x 1 5 x 30 Note Refer to page 23 for the dimensions of the mounting interface 6 x M10 x 1 5 x 30 6 x M10 x 1 5 x 30 Dimensions Model E I J K S 169 18 6 78 4 59 8 30 mm VXF26C Q Conduit terminal Con...

Page 24: ...e Refer to page 23 for the dimensions of the mounting interface 8 x M10 x 1 5 x 75 8 x M10 x 1 5 x 75 8 x M10 x 1 5 x 75 Dimensions Model E I J K S 167 18 6 78 4 59 8 30 mm VXF26D Q Grommet Grommet wi...

Page 25: ...r to page 23 for the dimensions of the mounting interface 8 x M10 x 1 5 x 75 8 x M10 x 1 5 x 75 8 x M10 x 1 5 x 75 Dimensions Model E I J K S 167 18 6 78 4 59 8 30 mm VXF26D Q Conduit terminal Conduit...

Page 26: ...6 x M10 x 1 5 x 20 C1 8 x M10 x 1 5 x 20 C1 7 x 4 5 2 2 5 187 5 0 2 1 7 0 80A Steel tube C 2 5 t o C 3 80 or more 89 1 0 8 11 6 16 4 24 2 10 Dimensions of the Mounting Interface Flange body I II type...

Page 27: ...4 1 1 1 2 73 84 132 66 74 110 66 74 110 36 45 63 64 5 74 5 106 19 23 5 35 40 47 77 53 5 64 5 95 29 5 29 5 32 mm VXFA21A VXFA22A VXFA23A Dimensions Model Port size P A B C D E F G H I J K L 2 136 112...

Page 28: ...F E 2 x P Port size A D Dimensions Model Port size P A D E F G H I J K 2 1 2 3 182 206 92 102 176 211 47 63 117 5 119 141 176 43 43 102 8 102 8 59 8 59 8 L 24 24 mm VXFA25A VXFA26A Dimensions Direct...

Page 29: ...18 3 34 34 34 17 17 17 17 47 50 50 50 43 43 43 43 102 8 102 8 102 8 102 8 L 24 24 24 24 Z 90 100 110 120 59 8 59 8 59 8 59 8 mm VXFA25B VXFA26B VXFA27B VXFA28B Dimensions Flange type VXFA25B VXFA26B V...

Page 30: ...8 0 2 R 1 80A Steel tube 34 0 2 80 or more 89 1 0 8 156 0 3 B R 2 R 1 7 x 45 2 2 5 178 0 2 8 x M10 x 1 5 x 20 C1 8 x M10 x 1 5 x 20 C1 178 0 2 90 or more 101 6 0 8 156 0 3 34 0 2 R 2 B R 1 R 1 90A Ste...

Page 31: ...97 5 132 5 17 32 106 15 49 1 4 Pilot port 43 59 8 102 8 1 2 Exhaust port 24 96 131 Note Refer to page 29 for the dimensions of the mounting interface 6 x M10 x 1 5 x 30 8 x M10 x 1 5 x 75 Dimensions F...

Page 32: ...3 80 or more 89 1 0 8 5 x 60 3 0 227 0 2 1 7 0 6 x M10 x 1 5 x 20 C1 8 x M10 x 1 5 x 20 C1 7 x 4 5 2 2 5 187 5 0 2 1 7 0 24 2 10 11 6 16 4 Dimensions of the Mounting Interface Flange body I II type P...

Page 33: ...ection LED10 LED9 LED8 LED7 COM FG AC2 AC1 LED 14 POW LED 13 IN LED 12 CAS LED 11 OUT LED6 LED5 LED4 LED3 LED2 LED1 1A ON OFF Specifications How to Order Controller Dimensions Model Input voltage Outp...

Page 34: ...ation degree of 5 m or less should be selected 3 Install an aftercooler or air dryer etc Compressed air that contains excessive drainage may cause malfunction of valves and other pneumatic equipment T...

Page 35: ...illate chatter Install them away from the valve or change the restriction 6 The header tank capacity should be sufficient This is a valve for large flow rate so if the capacity is too small the main v...

Page 36: ...the system 2 Shut off the power supply 3 Remove the product 2 Low frequency operation Switch valves at least once every 30 days to prevent malfunction Also in order to use it under the optimum state...

Page 37: ...6 N m w Conduit When used as an IP65 equivalent use seal to install the wiring conduit Also use the tightening torque below for the conduit There is no polarity Note Please order separately Rated volt...

Page 38: ...cations The output voltage to the solenoid valves will be the same as the input power supply voltage 2 Connect a ground that is rated Class 3 or greater to the power supply terminal block s FG 3 If th...

Page 39: ...36...

Page 40: ...e used in any of the following conditions 1 Conditions and environments outside of the given specifications or use outdoors or in a place exposed to direct sunlight 2 Installation on equipment in conj...