background image

Series

VQ0000

VQ1000

VQ2000

Porting specifications

Port 

location

Side

Side

Side

Port size

1(P), 3(R)

C6

C6

C8

4(A), 2(B)

C3, C4, M5

C3, C4, C6, M5

C4, C6, C8

Applicable 

stations

Max. 16 stations

Max. 16 stations

Max. 16 stations

Manifold Specifications

VV5Q04

VV5Q14

VV5Q14

VV5Q24

Flat Ribbon Cable (26 pins)

AXT100-FC26-1 to 3

Connector manufacturers’ example

• Hirose Electric Co., Ltd.
• Sumitomo 3M Limited
• Fujitsu Limited

• Japan Aviation Electronics Industry, Ltd.
• J.S.T. Mfg. Co., Ltd.
• Oki Electric Cable Co., Ltd.

Cable length (L)

Assembly part no.

1.5 m

3 m

5 m

AXT100-FC26-1

AXT100-FC26-2

AXT100-FC26-3

Note

Cable 

26

 core

28

AWG

Flat Ribbon Cable Connector Assembly (Option)

How to Order Manifold

1

D

1 4

08

S

VV5Q

P

0
1
2

VQ0000

VQ1000

VQ2000

Series

Stations

Connector entry direction

01

1 station

16

16 stations

···

···

Cable (Length)

0
1
2
3

Without cable

With cable (1.5 m)

With cable (3 m)

With cable (5 m)

4

Plug lead unit/Flip

Manifold

U
S

Top entry

Side entry

Positive common

specifications

Negative common

 specifications

Terminal no.

Flat ribbon cable connector

Polarity

(+)

(+)

(+)

(+)

(+)

(+)

(+)

(+)

(+)

(+)

(+)

(+)

(+)

(+)

(+)

(+)

(–)

(–)

(–)

(–)

(–)

(–)

(–)

(–)

(–)

(–)

(–)

(–)

(–)

(–)

(–)

(–)

(–)

(–)

(+)

(+)

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

25

26

Cable assembly

Electrical wiring specifications

SOL.A
SOL.B
SOL.A
SOL.B
SOL.A
SOL.B
SOL.A
SOL.B
SOL.A
SOL.B
SOL.A
SOL.B
SOL.A
SOL.B
SOL.A
SOL.B

COM.

1 station

2 stations

{

{

3 stations

{

4 stations

{

5 stations

{

6 stations

{

7 stations

{

8 stations

{

COM.

  MIL flat ribbon cable connector reduces installation labor savings for 

electrical connection.

 Using the connector for flat ribbon cable (26P), (10P, 16P, 20P as an 

option) conforming to MIL standard permits the use of connectors put 

on the market and gives a wide interchangeability.

  Top or side receptacle position can be selected in accordance with 

the available mounting space.

 Maximum stations are 16.

Flat ribbon cable connector assembly can be ordered individually or included 
in a specific manifold model no. Refer to How to Order Manifold.

  For other commercial connectors, use a 26 pins type with 

strain relief conforming to MIL-C-83503.

Types with 10, 16, or 20 pin are also available. 
For details, refer to page 2-4-69.

The total number of stations is 
tabulated starting from station 
one on the D side.

As the standard electrical wiring specifications, double wiring (connected to 
SOL. A and SOL. B) is adopted for the internal wiring of each station for 8 
stations or less, regardless of valve and option types. Mixed single and 
double wiring is available as an option. For details, refer to page 2-4-69.

When using the negative common 
specifications, use valves for negative 
common. (Refer to page 2-4-69.)

When two or more symbols are 
specified, indicate them 
alphabetically.
Example) -DNS
P kits are DIN rail mounting styles, 
so include suffix -D.
Specify the wiring specifications on 
the manifold specification sheet.

For details, refer to 
page 2-4-69.

1 2 3   ················  Stations

D side

U side

VQ0000/1000/2000
Kit (Flat ribbon cable connector)

Note) 

Note) 

Note)

Triangle mark
indicator position

Connector
terminal no.

Terminal no.

Note)

Note 1)

Note 2)

Note 3)

P

Red

DIN rail mounting style

Special wiring specifications

(Except double wiring)

With name plate

Built-in silencer, direct exhaust

(U side only)

Option

D

 

(2)

K

 (3)

N

S

2-4-42

Summary of Contents for VQ2000 Series

Page 1: ...Side entry 25P Note 1 25P Note 1 26P Note 1 26P Note 1 Top entry Side entry The number of max stations differs from kit to kit Refer to the table below When two or more symbols are specified indicate...

Page 2: ...ed when the F P T S kits add a valve For part nos refer to Option on page 2 4 69 The C kits is applicable to 200 220 VAC LO and MO valves are used for F P T and S kits The plug connector and lead wire...

Page 3: ...kit Terminal block C kit Individual connector S kit Serial transmission unit VV5Q04 VQ0 40 VQ0 41 VQ1 40 VQ1 41 VQ2 40 VQ2 41 VV5Q14 VV5Q24 C3 3 2 C4 4 M5 M5 thread C3 3 2 C4 4 C6 6 M5 M5 thread C4 4...

Page 4: ...able 26P 10P 16P 20P as an option conforming to MIL standard permits the use of connectors put on the market and gives a wide interchangeability Top or side receptacle position can be selected in acco...

Page 5: ...um 16 stations M plug connector AC Latching M plug connector L plug connector AC Latching L plug connector 115 L pug connector 109 M plug connector 115 L pug connector 109 M plug connector Applicable...

Page 6: ...choose the option with built in silencer no exhaust port will be supplied on the D side end plate In this case mount a spacer for individual EXH on the 1st station For a flip plug in unit block plate...

Page 7: ...rted into an unused cylinder port and SUP EXH ports Purchasing order is available in units of 10 pieces It is used for mounting a manifold on a DIN rail The DIN rail mounting bracket is fixed to the m...

Page 8: ...anifold Name plate None Caution Single unit 1 5 37 5 17 5 C8 One touch fitting assembly for 8 C6 One touch fitting for 6 2 Rc 1 8 1 4 C6 C8 2 B A 4 4 5 5 69 5 40 6 5 41 5 33 22 9 5 9 5 80 39 5 For C6...

Page 9: ...ve side can retain its switching position after manipulation 6 Please contact SMC for long term energization applications 7 If the metal seal type goes down below the minimum operating pressure of sup...

Page 10: ...corporated in the end plate on both sides of the manifold base A dirty and choked element may reduce cylinder speed or cause malfunction Clean or replace the dirty element Remove the cover from the si...

Page 11: ...llow Orange Yellow Pink None None None None None None None White Black Black Red Red Red Black Black Dot marking Lead wire color Terminal no Connector width W F and P kits with the following number of...

Page 12: ...kit and S kit double wiring connected to SOL A and SOL B is adopted for each station regardless of the valve and option types Mixed single and double wiring is available as an option 1 How to order v...

Page 13: ...L Dimension Option Each manifold can be mounted on a DIN rail Order it by indicating an option symbol for DIN rail mounting style D In this case a DIN rail which is approx 30 mm longer than the manifo...

Page 14: ...e 1 Note 2 Note 3 Note 4 F kit T kit S kit is composed of a flat ribbon cable housing assembly AXT100 2 PU20 of q SI unit and w P kit 20 pins Since no connector assembly is included order it separatel...

Page 15: ...bon steel Stainless steel 2 1 r t Option Replacement Parts No Part no Description Material Number VVQ2000 80A 3 2 VVQ2000 80A 3 4 i o Seal Clip HNBR Stainless steel 12 12 Nil Common exhaust S Built in...

Reviews: