background image

Warning 

Warning 

Design / Selection

 

 

 

1. Confirm the specifications. 

Products represented in this manual are designed only for use 
in compressed air systems (including vacuum). 
Do not operate at pressures or temperatures, etc., beyond the 
range of specifications, as this can cause damage or 
malfunction. (Refer to the specifications.) 
Please contact SMC when using a fluid other than compressed 
air (including vacuum). 

We do not guarantee  against any damage if the product is 

used outside of the specification range. 

2. Actuator drive 

When an actuator, such as a cylinder, is to be driven using a 

valve, take appropriate measures (cover installation or 
approach prohibition) to prevent potential danger caused by 
actuator operation. 

3. Holding pressure (including vacuum) 

Since the valves are subject to air leakage, they cannot be 

used for applications such as holding pressure (including 
vacuum) in a pressure vessel. 

4. Not suitable for use as an emergency shutoff 

valve, etc.

 

The valves listed in this manual are not designed for safety 
applications such as an emergency shutoff valve. If the valves 
are used for the mentioned applications, additional safety 
measures should be adopted.   

5. Release of residual pressure

 

For maintenance purposes install a system for releasing 
residual pressure. 

6. 

Operation in a vacuum condition

 

When a valve is used for switching a vacuum, take measures 
to install a suction filter or similar to prevent external dust or 
other foreign matter from entering inside the valve. In addition, 
at the time of vacuum adsorption, be sure to vacuum at all 
times. Failure to do so may result in foreign matter sticking to 
the adsorption pad, or air leakage causing the workpiece to 
drop. 

7. Regarding a vacuum switch valve and a 

vacuum release valve 

If a non-vacuum valve is installed in the middle of piping 
system having a vacuum, the vacuum condition will not be 
maintained. Use a valve designed for use under vacuum 
condition. 

8. Ventilation 

Provide ventilation when using a valve in a confined area, such

 

as in a closed control panel. For example, install a ventilation 
opening, etc. in order to prevent pressure from increasing 
inside of the confined area. 

9 .Do not disassemble the product or make any 

modifications, including additional machining. 

Doing so may cause human injury and/or an accident. 

When the product is disassembled for maintenance, refer to 

“Overhaul  / Cleaning / Addition of  grease (VPA31*5V series: 

Vacuum Specification)”. 

 

Selection

 

 
 

1. Use in low temperature environments

 

Valve use is possible to temperature to 0

o

C. Take appropriate 

measures to avoid freezing or congealing of drain, water, etc. 

2. Pilot air 

The pilot port should be pressurized by a compressed air at 
the specified pressure.   

 
 
 
 
 
 
 
 
 
 
 
 
 

3. Mounting orientation 

Mounting orientation is free.

 

 

Mounting

 

 

 

1. Operation manual 

Install the products and operate them only after reading the 
operation manual carefully and understanding its contents. 
Also, keep the manual where it can be referred to as 
necessary. 

2. Ensure sufficient space for maintenance 

activities. 

When installing the products, allow access for maintenance. 

3. Tighten threads with the proper tightening 

torque. 

When installing the products, follow the listed torque 
specifications. 

4. If air leakage increases or equipment does not 

operate properly, stop operation.

 

Check mounting conditions when air and power supplies are 
connected. Initial function and leakage tests should be 
performed after installation. 

5. Painting and coating 

Warnings or specifications printed or affixed to the product 
should not be erased, removed or covered up. 
Please consult with SMC before applying paint to resinous 
parts, as this may have an adverse effect due to the solvent in 
the paint. 
 
 
 
 
 
 

VPA31

5 Series 

Precautions for 3 Port Air Operated  Valve 

 

 

 

Be sure to read before handling.

 

 

Caution 

- 4 - 

VP3145-OMH0005-D

 

Summary of Contents for VPA31 5 Series

Page 1: ...Doc no VP3145 OMH0005 D PRODUCT NAME 3 Port Air Operated Valve MODEL Series Product Number Series VPA31 5...

Page 2: ...Safety Instructions 2 3 Design 4 Selection 4 Mounting 4 Piping 5 Lubrication 5 Air Supply 5 Operating Environment 5 Maintenance 5 Specific Product Precautions 6 7 Trouble shooting 8 Remedy 9 1 VP3145...

Page 3: ...hen configuring the equipment 2 Only personnel with appropriate training should operate machinery and equipment The product specified here may become unsafe if handled incorrectly The assembly operati...

Page 4: ...duct 3 Prior to using SMC products please read and understand the warranty terms and disclaimers noted in the specified catalog for the particular products 2 Vacuum pads are excluded from this 1 year...

Page 5: ...iping system having a vacuum the vacuum condition will not be maintained Use a valve designed for use under vacuum condition 8 Ventilation Provide ventilation when using a valve in a confined area suc...

Page 6: ...15 to 30 20 to 22 Connection Female Thread G Uni thread size Wrench tightening angle after tightened by hand deg Tightening torque N m 1 8 30 to 45 3 to 4 3 8 15 to 30 8 to 9 1 2 15 to 30 14 to 15 2 T...

Page 7: ...re changes drastically 2 Humidity of ambient environment If the humidity rises take measures to prevent the adhesion of water droplets on the valve Maintenance 1 Perform maintenance inspection accordi...

Page 8: ...n and plug IN port in case of vacuum use 2 This valve has slight air leakage and can not be used for such purposes as holding air pressure including vacuum in the pressure container 3 Piping Vacuum Us...

Page 9: ...ns B C D of the bodyA 1E A too Note 1 Do not wash the O ring and the spool valve with organic solvent or such Note 2 It is suggested to use the silicone grease G 40M made by Shin Etsu Chemical Co Ltd...

Page 10: ...ort According to the failure check the cause of the failure from which seems to effect the failure more than the other and devise a countermeasure Failure Cause Operation failure Valve would not be sw...

Page 11: ...d temporary 3 Water splashed directely 4 Strong impact was given 5 Foreign matter such as drain and particle invaded Return us the failure valve in just the state when the failure occurred to the valv...

Page 12: ...ku Tokyo 101 0021 JAPAN Tel 81 3 5207 8249 Fax 81 3 5298 5362 URL http www smcworld com Note Specifications are subject to change without prior notice and any obligation on the part of the manufactur...