Remedy

No.

Remedy

Replace the valve.

- If the lubrication oil was incorrect, remove the oil by air blow and replace the valve.

Lubricate turbine oil class 1 (ISO VG32) surely after replacing the valve.

Check the lubrication amount is correct or not.

Check the pressure is within the specified pressure range.  Check the pressure is 

dropped or not when the valve is worked.

Replace the valve after removing foreign matter in the pipe by such as air blow.

Fix or replace the actuator.

1. Oil other than the specified one has been lubricated.
2. Lubrication has been stopped intermediately, or lubrication was suspended temporary.
3. Water splashed directely.
4. Strong impact was given.
5. Foreign matter such as drain and particle invaded.

 

 Return us the failure valve in just the state when the failure occurred to the valve.

If no improvement is achieved in spite of the above countermeasure, inside of the valve may have some
failure.  In this case, stop using the valve immediately.

If any of followings are carried out, inside of the valve may have some failure.  In this case, stop using
the valve immediately.

6. Prohibited way of using the valve which is written at ''Precautions'' section in this operation
    manual was carried out  excluding above-mentioned.

- When a large quantity of drain is given and cannot carry out drain omission surely,
install either an auto-drain or a dryer.The valve should be replaced.

 

- 10 - 

  VP3145-OMH0005-D

 

Summary of Contents for VPA31 5 Series

Page 1: ...Doc no VP3145 OMH0005 D PRODUCT NAME 3 Port Air Operated Valve MODEL Series Product Number Series VPA31 5...

Page 2: ...Safety Instructions 2 3 Design 4 Selection 4 Mounting 4 Piping 5 Lubrication 5 Air Supply 5 Operating Environment 5 Maintenance 5 Specific Product Precautions 6 7 Trouble shooting 8 Remedy 9 1 VP3145...

Page 3: ...hen configuring the equipment 2 Only personnel with appropriate training should operate machinery and equipment The product specified here may become unsafe if handled incorrectly The assembly operati...

Page 4: ...duct 3 Prior to using SMC products please read and understand the warranty terms and disclaimers noted in the specified catalog for the particular products 2 Vacuum pads are excluded from this 1 year...

Page 5: ...iping system having a vacuum the vacuum condition will not be maintained Use a valve designed for use under vacuum condition 8 Ventilation Provide ventilation when using a valve in a confined area suc...

Page 6: ...15 to 30 20 to 22 Connection Female Thread G Uni thread size Wrench tightening angle after tightened by hand deg Tightening torque N m 1 8 30 to 45 3 to 4 3 8 15 to 30 8 to 9 1 2 15 to 30 14 to 15 2 T...

Page 7: ...re changes drastically 2 Humidity of ambient environment If the humidity rises take measures to prevent the adhesion of water droplets on the valve Maintenance 1 Perform maintenance inspection accordi...

Page 8: ...n and plug IN port in case of vacuum use 2 This valve has slight air leakage and can not be used for such purposes as holding air pressure including vacuum in the pressure container 3 Piping Vacuum Us...

Page 9: ...ns B C D of the bodyA 1E A too Note 1 Do not wash the O ring and the spool valve with organic solvent or such Note 2 It is suggested to use the silicone grease G 40M made by Shin Etsu Chemical Co Ltd...

Page 10: ...ort According to the failure check the cause of the failure from which seems to effect the failure more than the other and devise a countermeasure Failure Cause Operation failure Valve would not be sw...

Page 11: ...d temporary 3 Water splashed directely 4 Strong impact was given 5 Foreign matter such as drain and particle invaded Return us the failure valve in just the state when the failure occurred to the valv...

Page 12: ...ku Tokyo 101 0021 JAPAN Tel 81 3 5207 8249 Fax 81 3 5298 5362 URL http www smcworld com Note Specifications are subject to change without prior notice and any obligation on the part of the manufactur...

Reviews: