background image

- 7 -

 

VP4

*

50

*

-OMC0001-B   

Warning 

Warning 

Operating Environment 

 
 

1.

 

  

 

Do  not  use  in  an  atmosphere  having  corrosive  gases, 

chemicals,  sea water, water, water  steam,  or where  there  is 
direct contact with any of these . 

2.  Do  not  use  in  an  environment  where  flammable  gas  or 

explosive gas exists.    Usage may cause a fire or explosion. 
The products do not have an explosion proof construction. 

3.  Do  not  use  in  a  place  subject  to  heavy  vibration  and/or 

shock. 

4. The valve should not be exposed to prolonged sunlight. Use 

a protective cover. 

5. Remove any sources of excessive heat. 
6. If it used in an environment where there is possible contact 

with oil, weld spatter, etc., exercise preventive measures. 

7. When the solenoid valve is mounted in a control panel or its 

energized for a long time, make sure ambient temperature is 
within the specification of the valve.
 

8. Install silencer in EA/EB/Pilot EXH port to prevent dust from 

entering in the dusty ambient.   

 
 

1. Temperature of ambient environment 

I

 

Use  the  valve  within  the  range  of  the  ambient  temperature 

specification of each valve. In addition, pay attention when using 
the valve in environments where the temperature changes drastically. 

2. Humidity of ambient environme 

When  using  the  valve  in  environments  with  low  humidity,  take

 

measures to prevent static. 

If the humidity rises, take measures to prevent the adhesion of 

water droplets on the valve. 

 

Maintenance 

 
 

1. Perform maintenance inspection according to the 

procedures indicated in the operation manual.   

If  handled improperly, malfunction  and  damage  of machinery  or 
equipment may occur. 

2.

   

   

   

   

Removal  of  equipment,  and  supply/exhaust  of 

compressed air 

When components are removed, first confirm that measures are 
in place to prevent workpieces from dropping, run-away equipment, 
etc.  Then,  cut  off  the  supply  pressure  and  electric  power,  and 
exhaust  all  compressed  air  from  the  system  using  the  residual 
pressure release function. 
For 3-position closed center type, exhaust the residual pressure 
between the valve and the cylinder. 
When the equipment is operated after remounting or replacement, 
first  confirm  that  measures  are  in  place  to  prevent  lurching  of 
actuators,  etc.  Then,  confirm  that  the  equipment  is  operating 
normally. 

3. Low frequency operation 

Valves should be operated at least once every 30 days to prevent 
malfunction. (Use caution regarding the air supply.) 

4. Manual override 

When the manual override is operated, connected equipment will 
be actuated. Operate after safety is confirmed. 
 
 
 

5.

   

   

   

   

If  the  volume  of  air  leakage  increases  or  the 

valve does not operate normally, do not use the 
valve. 

Perform  periodic  maintenance  of  the  valve  to 

confirm  the  operating  condition,  and  if  there  is 
any air leakage. 

 

 

 
1. Drain flushing 

Remove drainage from the air filters regularly.   

2. Lubrication 

This  solenoid  valve  requires  lubrication,  once  lubrication  has 
been started, it must be continued. 
Use  class  1  turbine  oil  (with  no  additive),  ISO  VG32  because  if 
other  lubricant  oil  is  used,  it  may  cause  malfunction.  Please 
contact SMC for suggested class 2 turbine oil (with additive), ISO 
VG32. 

 

Caution 

Caution 

VP4

*

*

*

*

50/VP4

*

*

*

*

70/VVP4

*

*

*

*

0  Series 

Precautions  for  5  Port  Air  Operated  Valve 

4444

 

 

Be sure to read before handling.   

Summary of Contents for VP4 Series

Page 1: ...Doc No VP4 50 OMC0001 B PRODUCT NAME 5 Port Solenoid Valve MODEL Series Product Number VP4 50 VP4 70 VVP4 0 Series...

Page 2: ...0001 B Contents Safety Instructions 2 3 Design Selection 4 5 Mounting 5 Piping 6 Wiring 6 Lubrication 6 Air Supply 6 Operating Environment 7 Maintenance 7 Specific Product Precautions 8 Trouble Shooti...

Page 3: ...equipment failure when configuring the equipment 2 Only personnel with appropriate training should operate machinery and equipment The product specified here may become unsafe if handled incorrectly...

Page 4: ...ty a replacement product or necessary parts will be provided This limited warranty applies only to our product independently and not to any other damage incurred due to the failure of the product 3 Pr...

Page 5: ...e actuator 9 Ventilation Provide ventilation when using a valve in a confined area such as in a closed control panel For example install a ventilation opening etc in order to prevent pressure from inc...

Page 6: ...Operation manual Install the products and operate them only after reading the operation manual carefully and understanding its contents Also keep the manual where it can be referred to as necessary 2...

Page 7: ...alfunction If a lubricant is used in the system use class 1 turbine oil no additive ISO VG32 2 Please contact SMC regarding class 2 turbine oil with additive ISO VG32 Air Supply 1 Type of fluids Pleas...

Page 8: ...handled improperly malfunction and damage of machinery or equipment may occur 2 Removal of equipment and supply exhaust of compressed air When components are removed first confirm that measures are i...

Page 9: ...k 3 there is a cut out indicated by arrow 3a If a small flat head screwdriver is inserted into the cut out in the bottom the terminal block 3 can be removed from the cover 4 4 Remove the cable gland 5...

Page 10: ...eems most likely and implement countermeasures Intrusion of foreign matter Air leaks throuth gasket Insufficient bolt tightening Swollen spool seal Inefficient lubrication Burnt coil Voltage outside o...

Page 11: ...t has been subjected to strong impact 5 Foreign matter such as moisture or particles have entered the valve Please return the failed valve to SMC in the exact state when the failure occurred When a la...

Page 12: ...CV 4 14 1 Sotokanda Chiyoda ku Tokyo 101 0021 JAPAN Tel 81 3 5207 8249 Fax 81 3 5298 5362 URL http www smcworld com Note Specifications are subject to change without prior notice and any obligation o...

Reviews: