Remedy

No.

Remedy

Connect the wires again correctly.

Replace the part.

Replace the part or connect wires securely.

Replace pilot valve assembly.

Adjust pressure so that pilot pressure is within operating pressure range during opretation.

- If the lubrication oil was incorrect, remove the oil by air blow and replace the valve.

Lubricate with turbine oil class 1 (ISO VG32) after replacing the valve.

Check voltage. Replace pilot valve assembly.

Fix or replace the actuator.

Isolate the valve and re-tighten the bolts.

Replace pilot valve assembly.

Regulate voltage so that the voltage when operating is within the specified range.

1. Valve has been lubricated with a type of oil other than the specified type.
2. Lubrication has been stopped, or temporarily suspended.
3. The product has been directly exposed to water.
4. The product has been subjected to strong impact.
5. Foreign matter such as moisture or particles have entered the valve.

 Please return the failed valve to SMC in the exact state when the failure occurred.

- When a large amount of moisture is generated and cannot be removed, install either
an auto-drain or a dryer, and replace the valve.

To remove foreign matter, clean the pipe by air blow. Replace valve.

If lubricating oil has not been supplied, supply it. If a lubricator is installed, check it for
oil level and whether it is dropping oil properly.

If no improvement is achieved even when these countermeasures are implemented, the inside of the
valve may be damaged. In this case, stop using the valve immediately.

If any of the following actions have been carried out, the inside of the valve may be damaged.  In this
case, stop using the valve immediately.

Protect the valve so that water does not splash the coil. Replace valve.
Replace pilot valve assembly.

6. The valve has been used in a way prohibited in the ''Precautions'' section in this operation manual.

 

 

Summary of Contents for VP4 Series

Page 1: ...Doc No VP4 50 OMC0001 B PRODUCT NAME 5 Port Solenoid Valve MODEL Series Product Number VP4 50 VP4 70 VVP4 0 Series...

Page 2: ...0001 B Contents Safety Instructions 2 3 Design Selection 4 5 Mounting 5 Piping 6 Wiring 6 Lubrication 6 Air Supply 6 Operating Environment 7 Maintenance 7 Specific Product Precautions 8 Trouble Shooti...

Page 3: ...equipment failure when configuring the equipment 2 Only personnel with appropriate training should operate machinery and equipment The product specified here may become unsafe if handled incorrectly...

Page 4: ...ty a replacement product or necessary parts will be provided This limited warranty applies only to our product independently and not to any other damage incurred due to the failure of the product 3 Pr...

Page 5: ...e actuator 9 Ventilation Provide ventilation when using a valve in a confined area such as in a closed control panel For example install a ventilation opening etc in order to prevent pressure from inc...

Page 6: ...Operation manual Install the products and operate them only after reading the operation manual carefully and understanding its contents Also keep the manual where it can be referred to as necessary 2...

Page 7: ...alfunction If a lubricant is used in the system use class 1 turbine oil no additive ISO VG32 2 Please contact SMC regarding class 2 turbine oil with additive ISO VG32 Air Supply 1 Type of fluids Pleas...

Page 8: ...handled improperly malfunction and damage of machinery or equipment may occur 2 Removal of equipment and supply exhaust of compressed air When components are removed first confirm that measures are i...

Page 9: ...k 3 there is a cut out indicated by arrow 3a If a small flat head screwdriver is inserted into the cut out in the bottom the terminal block 3 can be removed from the cover 4 4 Remove the cable gland 5...

Page 10: ...eems most likely and implement countermeasures Intrusion of foreign matter Air leaks throuth gasket Insufficient bolt tightening Swollen spool seal Inefficient lubrication Burnt coil Voltage outside o...

Page 11: ...t has been subjected to strong impact 5 Foreign matter such as moisture or particles have entered the valve Please return the failed valve to SMC in the exact state when the failure occurred When a la...

Page 12: ...CV 4 14 1 Sotokanda Chiyoda ku Tokyo 101 0021 JAPAN Tel 81 3 5207 8249 Fax 81 3 5298 5362 URL http www smcworld com Note Specifications are subject to change without prior notice and any obligation o...

Reviews: