VT325 Series
Specific Product Precautions (1)
Be sure to read this before handling the products.
How to Use DIN Terminal
1. Disassembly
1) After loosening the screw (1), then if the housing (4) is pulled in
the direction of the screw (1), the connector will be removed
from the body of equipment (solenoid, etc.).
2) Pull out the screw (1), then remove the gasket (2).
3) On the bottom part of the terminal block (3), there’s a cut-off
part (indication of an arrow) (3a). If a small flat head
screwdriver is inserted between the opening in the bottom,
terminal block (3) will be removed from the housing (4).
(Refer to graph at right.)
4) Remove the cable gland (5) and plain washer (6) and rubber
seal (7).
2. Wiring
1) Pass the cable (8) through the cable gland (5), washer (6),
rubber seal (7), in this order and then insert them into the
housing (4).
2) Dimensions of the cable (8) are as shown in the right figure.
Skin the cable and crimp the crimped terminal (9) to the edges.
3) Remove the screw (3f) from the bracket (3e). (Loosen in the
case of Y-shape type terminal.) As shown in the right figure,
mount a crimped terminal (9), and then again tighten the screw
(3f).
Note) Tighten within the tightening torque of 0.5 N·m
±
15%.
Note: a) It is possible to wire even in the state of bare wire. In that
case, loosen the screw (3f)
and place a lead wire into
the bracket (3d), and then tighten it once again.
b) The maximum size for the round terminal (9) is 1.25 mm
2
- 3.5
and for the Y terminal is 1.25 mm
2
- 4.
c) Cable (8) outside diameter:
φ
6 to
φ
12 mm
Note) For the one with outside diameter ranged between
φ
9 to
φ
12 remove the inside parts of the rubber seal (7) before
using.
3. Assembly
1) Terminal block (3) connected with housing (4) should be
reinstated. (Push it down until you hear the click sound.)
2) Putting rubber seal (7), plain washer (6), in this order into the
cable introducing slit on the housing (4), then further tighten the
cable gland (5) securely.
3) By inserting gasket (2) between the bottom part of the terminal
block (3) and a plug on an equipment, screw in (1) on top of the
housing (4) and tighten it.
Note) Tighten within the tightening torque of 0.5 N·m
±
20%.
Changing the entry direction
The cable entry direction of a connector can be changed as
desired (4 directions at 90° intervals), depending on the
combination of a housing (4) and a terminal block (3).
Wiring
If the rated voltage for the solenoid valve is DC type, connect the
terminal No.1 to the positive (+) side and No.2 to the negative (-)
side.
Connector for DIN Terminal
Description
Part no.
DIN connector
GDM2C
Exploded view
- 8 -
No.VT325
∗∗
-OMK0002-B