Installation and Maintenance Manual
Series VJ100/300/500/700 Solenoid Valves

This manual should be read in conjunction with the current valve catalogue

For future reference, please keep this manual in a safe place

Safety Instructions

These safety instructions are intended to prevent a hazardous situa-
tion and/or equipment damage.These instructions indicate the level
of potential hazard by label of “Caution”, “Warning” or “Danger”.
To ensure safety, be sure to observe ISO4414 

(Note1)

, JIS B 8370 

(Note2)

and other safety practices.
Note 1: ISO 4414: Pneumatic fluid power – Recommendations for the
application of equipment to transmission and control systems.
Note 2: JIS B 8370: Pneumatic system axiom.

CAUTION :

Operator error could result in injury or

equipment damage.

WARNING:

Operator error could result in serious

injury or loss of life.

DANGER :

In extreme conditions, there is a 

possible result of serious injury or loss of life.

WARNING

1. The compatibility of pneumatic equipment is the respon-

sibility of the person who designs the pneumatic system
or decides its specifications.

Since the products specified here are used in various operating
conditions, their compatibility for the specific pneumatic system
must be based on specifications or after analysis and/or tests to
meet your specific requirements.

2. Only trained personnel should operate pneumatically

operated machinery and equipment.

Compressed air can be dangerous if an operator is unfamiliar 
with it. Assembly, handling or repair of pneumatic systems should
be performed by trained and experienced operators.

3. Do not service machinery/equipment or attempt to

remove component until safety is confirmed.

1)  Inspection and maintenance of machinery/equipment should

only be performed after confirmation of safe locked-out 
control positions.

2)  When equipment is to be removed, confirm the safety process

as mentioned above. Switch off air and electrical supplies and
exhaust all residual compressed air in the system.

3)  Before machinery/equipment is re-started, ensure all safety

measures to prevent sudden movement of cylinders etc.
(Bleed air into the system gradually to create back-pressure,
i.e. incorporate a soft-start valve).

4. Contact SMC if the product is to be used in any of the 

following conditions:

1)  Conditions and environments beyond the given specifica-

tions, or if product is used outdoors.

2)  Installations in conjunction with atomic energy, railway, air

navigation, vehicles, medical equipment, food and beverage,
recreation equipment, emergency stop circuits, press 
applications, or safety equipment.

3)  An application which has the possibility of having negative

effects on people, property, or animals, requiring special 
safety analysis.

CAUTION

Ensure that the air supply system is filtered to 5 micron.

VJ100  (3 Port)

Specifications

Fluid

Air and inert gases

Ambient and fluid temperature

Max. 50°C

Response time

10ms or less

Max. operating frequency

20c/s

Manual override

Non-locking type, slotted locking type

Lubrication

Not required

Mounting position

Free

Impact/Vibration resistance

15G/3G (8.3~2000Hz)

Enclosure

IP40

Solenoid specifications

Electrical entry

Grommet (G) (H), plug connector (L or M)

Voltages

24VDC, 12VDC, 6VDC, 5VDC, 3VDC

Allowable voltage

±10% of rated voltage

Coil insulation

Class A

Power consumption

1W (with LED: 1.2W)

Surge voltage suppressor

Diode

Indicator light

LED

Tube Connection (Fig 3)

Ensure that the tube 

5

is cut square.

Push tube 

5

into the fitting 

7

until it stops.

Pull back on tube 

5

to ensure it is gripped by retainer 

4

.

Tube disconnection (Fig 3)

Push down on the collet 

1

.

Holding down the collet 

1

, withdraw the tube from the fitting 

5

.

CAUTION

Connecting plug connector (Fig 4)

Ensure the connector is pushed onto the pins in a straight line.
Ensure that the lip of the lever is securely positioned in the groove in
the solenoid cover.

Disconnecting plug connector (Fig 4)

1. Press the lever against the connector and pull the connector away

from the solenoid in a straight line.

Surge voltage protection circuit (Fig 5)

Ensure the lead wires are correctly connected to the + (Plus) and
Minus (-) indications on the connector.
Incorrect connection may result in the diode or switching element
becoming damaged.
Those solenoids with pre-wired leads are + side Red wire, and - side
Black wire.

Lamp and surge voltage suppression (Fig 6)

Solenoid manual override operation (Fig 7)

CAUTION

Ensure all SAFETY precautions are in position before operating 
manual overrides as connected equipment will commence operation.
VJ300, VJ3000 have manual overrides in two positions, i.e. on the pilot
operator and on the valve body.
Push and turn. Can be used as non-locking type if the operator is
just pushed without turning

Push non lock type (Fig 7) valve body

1. Push down on the orange button using a small screwdriver until

it stops.

2. Hold this position until all checks have been completed.
3. Release the orange button and the override will reset to the OFF position.

Push lock manual override (Fig 7)

Locking

1. Push down on the orange button using a small screwdriver until it stops.
2. Turn the button through 90° clockwise.
3. Remove the screwdriver.

WARNING

In this position the manual override is in the locked ON position.

Unlocking

1. Using a small screwdriver turn the manual override 90°

anti-clockwise.

2. Remove the screwdriver and the manual override will reset to the

OFF position.

Leakage voltage (Fig 8)

Note: When using a resistor in parallel with a contact, the leakage
voltage may increase due to the leakage current flowing through the
resister.
* Leakage voltage must be no more than 3% of the rated voltage.

Blanking plate assembly (Fig 10)

043A/ENG

When you enquire about the product, please contact the following 

SMC Corporation

:

ENGLAND

Phone 01908-563888

TURKEY

Phone 212-2211512

ITALY

Phone 02-92711

GERMANY

Phone 6103-402-0

HOLLAND

Phone 020-5318888

FRANCE

Phone 01-64-76-10-00

SWITZERLAND

Phone 052-396-31-31

SWEDEN

Phone 08-603 07 00

SPAIN

Phone 945-184100

AUSTRIA

Phone 02262-62-280

Phone 902-255255

IRELAND

Phone 01-4501822

GREECE

Phone 01-3426076

DENMARK

Phone 70 25 29 00

FINLAND

Phone 09-68 10 21

NORWAY

Phone 67-12 90 20

BELGIUM

Phone 03-3551464

POLAND

Phone 48-22-6131847

Installation

WARNING

Ensure all air and power supplies are ISOLATED before commencing
installation.
Do not install these valves in explosive atmospheres.
If these valves are exposed to oil and/or water droplets ensure that
they are protected.
If it is intended to energise a valve for an extended period of time
please consult SMC.

VJ100  (3 Port)

Symbol

N.C

2

2

3

R3

1

1

N.O

Fig 1

Fig 3

Fig 4

Fig 5

Fig 9

Fig 10

Fig 6

Fig 7

Fig 2

Construction/Parts list (Fig 2)

8 1 6

3

4

9 7 2 5

K

J

Main parts

No.

Parts name

Material

Notes

1

Body

PBT resin

Black

2

Cover

Polyacetal

Black

3

Push rod

Polyacetal

-

4

Armature assembly

NBR stainless steel

-

5

Core

Stainless steel

-

6

Exhaust poppet

NBR

-

7

Return spring

Stainless steel

-

8

Poppet spring

Stainless steel

-

9

Coil assembly

-

-

Spare parts

No.

Parts name

Material

Parts No.

J

Gasket

NBR

VJ100-6-1

K

Subplate

Zinc die cast

NVJ100-17-1

N.C

2

3
4

6

1

5

7
8
9

1

Collet

2

Guide

3

Collar

4

Tube retainer

5

Tube

6

Tube seal

7

Body

8

O-ring

9

Stud

M type

L type

Cover

Groove

Pin

Cover

Groove

Pin

Lever

DC indicator

Connector

Hook

Socket
DXT170-71-1

Lead wire
0.2~0.33mm

2

(Max O.D.:
ø1.7mm)

Red

Diode

Black

Red

LED

Black

Coil

Coil

With indicator light

With surge voltage suppressor

With indicator light and surge voltage suppressor

Red

Black

Coil

Diode

Manual operator on
the pilot valve

Manual operator on
the valve body

Turn to the 
direction 
of arrow mark

Correct combination of solenoid valve, gasket and sub
base/manifold (Fig 9)

M1.7x13
Screw

VJ100-6-1
Gasket

Applicable base

• Subplate
• VV3J1-S41 type manifold base

M1.7x7
Screw

VJ100-19-1
Blanking plate

VJ100-20-1
Gasket

Applicable base

• Subplate
• VV3JI-S41 

type manifold 
base

Fig 8

Power 

source

Contacts

Resister

Valve

Voltage leakage

Current leakage

Red

Black

LED

Coil

VJ300 (3 Port)

Specifications

Fluid

Air and inert gases

Operating 

Internal pilot type

1.5~7 kgf/cm

2

pressure range

External pilot type

Main supply pressure

10 Torr~7 kgf/cm

2

External pilot pressure

1.5~7 kgf/cm

2

Ambient and fluid temperature

Max. 50°C

Response time

15ms or less

Max. operating frequency

10 c/s

Manual override

Non-locking push type, slotted locking type

Pilot exhaust

Individual pilot exhaust, common exhaust for main and pilot valve

Lubrication

Not required

Mounting position

Free

Impact/vibration resistance

15G/3G (8.3~2000Hz)

Enclosure

IP40

Solenoid specifications

Electrical entry

Grommet (G) (H)   Plug connector (L or M)

Voltage

24VDC, 12VDC, 6VDC, 5VDC, 3VDC

Allowable voltage

±10% of rated voltage

Coil insulation

Class A or equivalent

Power consumption

1W (with LED: 12W)

Surge voltage suppressor

Diode

Indicator light

LED