1. Preparation before piping

 

Before piping is connected, it should be thoroughly blown 

out  with  air  (flushing)  or  washed  to  remove chips, cutting 

oil and other debris from inside the pipe. 

2. Wrapping of pipe tape 

When  screwing  piping  or  fittings  into  ports,  ensure  that 

chips  from  the  pipe  threads  or  sealing  material  do  not 

enter the piping. Also, if pipe tape is used, leave 1 thread 

ridge exposed at the end of the threads. 

 

 

 

 

 

 

 

 

 

3. Closed center type 

For  closed  center  type,  check  the  piping  to  prevent  air 

leakage  from  the  piping  between  the  valve  and  the 

cylinder. 

4. Connection of fittings 

When screwing fittings into valves, tighten as follows. 

Rc 

Tighten with the proper torque shown below. 

Tightening Torque for Piping 

Connection thread 

Proper tightening torque (N

m  ) 

Rc1/8 

7 to 9 

Rc3/4 

28 to 30 

Rc1 

36 to 38 

Follow  the  procedure  of  the  manufacturer  when  fittings 

other than SMC is used. 

 

Wiring 

 

 

1. Polarity 

There is no polarity. 

2. Applied voltage 

When electric power is connected to a solenoid valve, be 

careful to apply the proper voltage. Improper voltage may 

cause malfunction or coil damage. 

3. Check the connections. 

Check  if  the  connections  are  correct  after  completing  all 

wiring. 

 
 

 

1. Lubrication 

1)  The valve has been lubricated for life by the factory, and 

does not require any further.   

2)  If a lubricant is used in the system, use class 1 turbine oil 

(no additive), ISO VG32. 

Once a lubricant is used in the system, lubrication must 

be continued because the original lubricant applied 

during manufacturing will be washed away. 

If turbine oil is used, refer to the Material Safety Data 

Sheet (MSDS) of the oil. 

3)  Please contact SMC regarding class 2 turbine oil (with 

additives), ISO VG32. 

 

Air Supply 

 
 

 

1. Type of fluids 

Please  consult  with  SMC  when  using  the  product  in 

applications other than compressed air. 

2. When there is a large amount of drainage. 

Compressed  air  containing  a  large  amount  of  drainage 

can  cause  malfunction  of  pneumatic  equipment.  An  air 

dryer  or  water  separator  should  be  installed  upstream 

from filters. 

3. Drain flushing 

If  condensation  in  the  drain  bowl  is  not  emptied  on  a 

regular  basis,  the  bowl  will  overflow  and  allow  the 

condensation to enter the compressed air lines. It causes 

malufunction of pneumatic equipment. 

If  the  drain  bowl  is  difficult  to  check  and  remove, 

installation  of  a  drain  bowl  with  an  auto  drain  option  is 

recommended. 

For compressed air quality, refer to SMC’s Best Pneumatics 

catalog. 

4. Use clean air. 

Do  not  use  compressed  air  that  contains  chemicals, 

synthetic  oils including  organic solvents,  salt  or corrosive 

gases, etc., as it can cause damage or malfunction. 

 

 

 

Piping 

Lubrication 

VFR6000  Series 

5 Port Solenoid Valve / Precautions 3

    

 

Be sure to read before handling.

    

 

Caution 

 

Warning 

 

Caution 

 

Warning 

Summary of Contents for VFR6 00 Series

Page 1: ...Doc No VFR6000 OMA0001 B 5 Port Solenoid Valve PRODUCT NAME VFR6000 Series MODEL Series...

Page 2: ...afety Instructions 2 3 Precautions on Design 4 5 Selection 4 5 Mounting 5 Piping 6 Wiring 6 Lubrication 6 Air Supply 6 7 Operating Environment 7 Maintenance 7 Specific Product Precautions 8 9 10 Troub...

Page 3: ...of equipment failure when configuring the equipment 2 Only personnel with appropriate training should operate machinery and equipment The product specified here may become unsafe if handled incorrect...

Page 4: ...placement product or necessary parts will be provided This limited warranty applies only to our product independently and not to any other damage incurred due to the failure of the product 3 Prior to...

Page 5: ...on closed center valve or double check valve type ensure that the residual pressure between the valve and the cylinder is released 7 Double solenoid type When using the double solenoid type for the fi...

Page 6: ...voltage will remain Therefore take into consideration the surge voltage protection of the controller In the case of diodes the residual voltage is appro ximately 1V 5 Operation in a low temperature c...

Page 7: ...does not require any further 2 If a lubricant is used in the system use class 1 turbine oil no additive ISO VG32 Once a lubricant is used in the system lubrication must be continued because the origi...

Page 8: ...e contact with oil weld spatter etc exercise preventive measures 7 When the solenoid valve is mounted in a control panel or its energized for a long time make sure ambient temperatures is within the s...

Page 9: ...le cable Cross section of the wire 0 5 to 1 5mm2 Cable O D 8 to 10mm Applicable terminal 1 25Y 3L 1 25 3 5S 1 25 4M Terminal block type Remove cover 1 over terminal block 2 attached to the inside of b...

Page 10: ...id valve Loosen set screw and take solenoid valve out vertically otherwise it may cause damage to the solenoid valve Never remove valve at an angle When mounting solenoid valve on to the base plug pin...

Page 11: ...assembly like the following figure Note Do not change the rated voltage Change Direction of DIN Connector Cable Entry Unscrew retaining screw pull off outer cover rotate connector block through 180o...

Page 12: ...t specification Remedy Spool valve has not completely shifted 1 2 3 4 6 Coil splashed by water Low pilot pressure Intrusion of foreign matter Leakage Worn spool packing Poor seal on actuator cylinder...

Page 13: ...ve assembly 11 To remove foreign matter clean the pipe by air blow Replace valve 12 Repair or replace actuators Isolate the valve and re tighten the bolts 13 If no improvement is achieced in spite of...

Page 14: ...rinting AZ 4 14 1 Sotokanda Chiyoda ku Tokyo 101 0021 JAPAN Tel 81 3 5207 8249 Fax 81 3 5298 5362 URL http www smcworld com Note Specifications are subject to change without prior notice and any oblig...

Reviews: