background image

- 12 - 

 

VFR6000-OMA0001-B

 

 

 

 

REMEDY 

 

 

(5)

Replace valve.

(9)

Check voltage. Replace pilot valve assem bly.

(6)

Replace pilot valve assem bly.

(7)

Adjust pressure so that pilot pressure will fall within operating pressure range during opretation.

(8)

-If worng oil used, com pletely air blow to rem ove oil and replace valve. After valve is replaced,
use turbine oil class 1 (ISO VG32).

No.

Remedy

(2)

Re-wire correctly.

(1)

Regulate voltage, so that the voltage at the tim e of the operationbecom es specifications range.

(3)

Replace part.

(4)

Replace part or re-wire positively.

-W hen a large quantity of drain is given and cannot carry out drain om ission surely, install
either an auto-drain or a dryer. The valve should be replaced.

(14)

Lessen the oil supply am ount to the degree that oill does not spout out of the exhaust port
[3(EB), 5(EA), PE port]. *In the case of N.O. specification, 1(P) port.

(10)

Protect the valve so that water does not splash the coil. Replace pilot valve assem bly.

(11)

To rem ove foreign m atter, clean the pipe by air blow. Replace valve.

(12)

Repair or replace actuators.

Isolate the valve and re-tighten the bolts.

(13)

If no im provem ent is achieced in spite of the above counterm easure, inside of the valve m ay have som e
abnom ality. In this case, stop using the balbe im m ediately

If any of followings are carried out, inside of the valve m ay have som e failure. In this case, stop usig the
valve im m ediately

(15)

Supply specified pressure to X port.
(Single solenoid, 3 position: 0.2 to 0.9 MPa, Double solenoid: 0.1 to 0.9 MPa)

W ater splashed directely.

4.

Strong im pact was given.

Voltage out of rated voltage has been used.

1.

Oil other than specified one has been lubricated.

2.

5.

Lubrication has been stopped interm ediately, or lubrication was suspended tem porary.

3.

In addition, in the case of trouble, please send it back to the supplier for repair or replacem ent.

Alien substance such as drain and particle got into. Drainor garbage invaded a valve.

6.

Prohibitted way of using the balbe which is written at "Precautions" section in this operation m anual
was carride out excluding above -m entioned.

7.

Summary of Contents for VFR6 00 Series

Page 1: ...Doc No VFR6000 OMA0001 B 5 Port Solenoid Valve PRODUCT NAME VFR6000 Series MODEL Series...

Page 2: ...afety Instructions 2 3 Precautions on Design 4 5 Selection 4 5 Mounting 5 Piping 6 Wiring 6 Lubrication 6 Air Supply 6 7 Operating Environment 7 Maintenance 7 Specific Product Precautions 8 9 10 Troub...

Page 3: ...of equipment failure when configuring the equipment 2 Only personnel with appropriate training should operate machinery and equipment The product specified here may become unsafe if handled incorrect...

Page 4: ...placement product or necessary parts will be provided This limited warranty applies only to our product independently and not to any other damage incurred due to the failure of the product 3 Prior to...

Page 5: ...on closed center valve or double check valve type ensure that the residual pressure between the valve and the cylinder is released 7 Double solenoid type When using the double solenoid type for the fi...

Page 6: ...voltage will remain Therefore take into consideration the surge voltage protection of the controller In the case of diodes the residual voltage is appro ximately 1V 5 Operation in a low temperature c...

Page 7: ...does not require any further 2 If a lubricant is used in the system use class 1 turbine oil no additive ISO VG32 Once a lubricant is used in the system lubrication must be continued because the origi...

Page 8: ...e contact with oil weld spatter etc exercise preventive measures 7 When the solenoid valve is mounted in a control panel or its energized for a long time make sure ambient temperatures is within the s...

Page 9: ...le cable Cross section of the wire 0 5 to 1 5mm2 Cable O D 8 to 10mm Applicable terminal 1 25Y 3L 1 25 3 5S 1 25 4M Terminal block type Remove cover 1 over terminal block 2 attached to the inside of b...

Page 10: ...id valve Loosen set screw and take solenoid valve out vertically otherwise it may cause damage to the solenoid valve Never remove valve at an angle When mounting solenoid valve on to the base plug pin...

Page 11: ...assembly like the following figure Note Do not change the rated voltage Change Direction of DIN Connector Cable Entry Unscrew retaining screw pull off outer cover rotate connector block through 180o...

Page 12: ...t specification Remedy Spool valve has not completely shifted 1 2 3 4 6 Coil splashed by water Low pilot pressure Intrusion of foreign matter Leakage Worn spool packing Poor seal on actuator cylinder...

Page 13: ...ve assembly 11 To remove foreign matter clean the pipe by air blow Replace valve 12 Repair or replace actuators Isolate the valve and re tighten the bolts 13 If no improvement is achieced in spite of...

Page 14: ...rinting AZ 4 14 1 Sotokanda Chiyoda ku Tokyo 101 0021 JAPAN Tel 81 3 5207 8249 Fax 81 3 5298 5362 URL http www smcworld com Note Specifications are subject to change without prior notice and any oblig...

Reviews: