- 10 -
VFR6000-OMA0001-B
How to Exchange Solenoid Valve, Pilot Valve Assembly
How to exchange pilot valve assembly
Possible to exchange pilot valve assembly like the following
figure.
Note) Do not change the rated voltage.
Change Direction of DIN Connector/Cable Entry
Unscrew retaining screw, pull off outer cover, rotate connector
block through 180
o
. Replace cover and tighten screw.
Pilot caver
Pilot valve
assembly
VFR6000 Series
Specific Product Precautions 3
Be sure to read before handling.