4 Settings 

  The outlet pressure is set by rotating the adjusting bolt, at the bottom of 

the regulator. SeeFigure 3.Loosen the locknut first. 

 

The adjusting bolt (32 mm across flats) can be rotated by a spanner, 

or with a screwdriver using the Ø11mm hole in the bolt head. 

 

Warning 

  Adjust the outlet pressure while confirming the pressure gauge values on 

the inlet and outlet sides. 

  Over-rotating the adjusting bolt will damage the inner components of the 

product. 

  The set outlet pressure should be less than 85% of the inlet pressure. 

  Setting the outlet pressure to more than 85% of the inlet pressure may 

cause  fluctuation  of  flow  or  pressure  on  the  inlet  side,  resulting  in 
unstable operation. 

  The  maximum  value  of  the  set  pressure  range  has  a  tolerance, 

therefore, the set pressure may exceed this value. 

 

Tighten the locknut when adjustment is complete.  The locknut is not 

an  anti-tamper  device.    Appropriate  measures  against  foreseeable 
misuse must be taken if this can cause a hazard. 

 

Caution 

  Adjust after carefully confirming the inlet pressure. 

  When adjusting the outlet pressure, a torque is applied to the adjusting 

bolt.  Support  the  product  separately,  so  that  the  torque  force  is  not 
transferred to the external piping. 

Reference for Adjusting bolt Torque 

Set pressure 

1 MPa 

2 MPa 

3 MPa 

4 MPa 

5 MPa 

Torque   N

·

12 

15 

Table 2 

  Setting  the  outlet  pressure  should  be  conducted  by  increasing  the 

pressure. 

  Setting  the  outlet  pressure  by  decreasing  the  pressure  may  result  in 

going below the required set pressure. 

  Turning  the  adjusting  bolt  in  the  clockwise  direction,  increases  the 

pressure. 

  Turning  the  adjusting  bolt  counter-clockwise,  will  decrease  the  outlet 

pressure. 

5 How to Order 

 

 

6 Outline Dimensions (mm) 

 

Figure 5

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

7 Maintenance 

7.1  General Maintenance 

 

This  product  does  not  require  maintenance.    However  the  following 

advice should be followed: 

 

Ensure  the  proper  function  of  the  regulator  is  regularly 

checked 

 

Ensure there is no build-up of dirt or debris on the regulator, 

especially around the vent ports and adjustment screw. 

Caution 

  Not following proper maintenance procedures could cause the product to 

malfunction and lead to equipment damage. 

  If  handled  improperly,  compressed  air  can  be  dangerous.  Maintenance 

of pneumatic systems should be performed only by qualified personnel. 

  Before performing maintenance, turn off the power supply and be sure to 

cut  off  the  supply  pressure.  Confirm  that  the  air  is  released  to 
atmosphere. 

  After installation and maintenance, apply operating pressure and power 

to  the  equipment  and  perform  appropriate  functional  and  leakage  tests 
to make sure the equipment is installed correctly. 

  Do not make any modification to the product. 

  Do  not  disassemble  the  product,  unless  required  by  installation  or 

maintenance instructions.

 

 

8 Limitations of Use 

 

Warning 

  This product must not be used as a safety accessory as defined by the 

Pressure Equipment Directive 97/23/EC. 

  Install a protective device if the outlet pressure exceeding the set outlet 

pressure could cause equipment damage or malfunction. 

  The outlet pressure may fluctuate when the air has not been consumed 

for a long time, or the product is used in a shut-off or balancing circuit on 
the outlet side. 

  Grease may leak into the outlet side, as it is applied to inner sliding parts 

and seals. 

  Do not use in circuits requiring highly precise relief sensitivity or setting 

precision. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

9 Contacts 

 

AUSTRIA 

(43) 2262 62280-0   

LATVIA 

(371) 781 77 00 

BELGIUM 

(32) 3 355 1464   

LITHUANIA 

(370) 5 264 8126 

BULGARIA 

(359) 2 974 4492  

NETHERLANDS 

(31) 20 531 8888  

CZECH REP. 

(420) 541 424 611   

NORWAY 

(47) 67 12 90 20  

DENMARK 

(45) 7025 2900   

POLAND 

(48) 22 211 9600  

ESTONIA 

(372) 651 0370  

PORTUGAL 

(351) 21 471 1880 

FINLAND 

(358) 207 513513   

ROMANIA 

(40) 21 320 5111 

FRANCE 

(33) 1 6476 1000   

SLOVAKIA 

(421) 2 444 56725  

GERMANY 

(49) 6103 4020   

SLOVENIA 

(386) 73 885 412 

GREECE 

(30) 210 271 7265   

SPAIN 

(34) 945 184 100  

HUNGARY 

(36) 23 511 390   

SWEDEN 

(46) 8 603 1200  

IRELAND 

(353) 1 403 9000   

SWITZERLAND 

(41) 52 396 3131  

ITALY 

(39) 02 92711  

UNITED KINGDOM 

(44) 1908 563888  

 

URL : 

http// www.smcworld.com (Global)      http// www.smceu.com (Europe)

 

Specifications are subject to change without prior notice from the manufacturer.  
© 

2013

 SMC Corporation All Rights Reserved. 

Reviews: