RoHS
2-position double
Manifold base
U side
1
2
Stations
3
D side
Refer to pages 160 (SY5000) and
161 (SY7000) for the dimensions
of Type 11/Bottom-ported type.
For details on the EX500 Gateway Type Serial Transmission
System, refer to the
Web Catalog and the Operation Manual.
For the part numbers of the SI units to be mounted, refer to
page 188. Please download the Operation Manual via the
SMC website, https://www.smcworld.com
*
A separate GW unit and communication cable are required.
Plug-in
Connector Connecting Base
EX500 Gateway Decentralized System 2 (128 Points)
SY3000/5000/7000
Series
SS5Y3-10SA3N-05D-C6···1 set (Manifold base part number)
*
SY3200-5U1···················5 sets (2-position double part number)
The asterisk denotes the symbol for the assembly.
Prefix it to the part numbers of the valve, etc.
•
For the valve arrangement, the valve closest to the D side is considered
the 1st station.
•
Under the manifold base part number, state the valves to be mounted
in order starting with the 1st station as shown in the figure above. If the
arrangement becomes too complicated, specify the details on a
manifold specification sheet.
How to Order Manifolds
SS5Y
S
10
3
C6
How to Order Manifold Assembly
05
*
1 Double wiring: 2-position single, double,
3-position, and 4-position valves can be
used on all manifold stations.
Use of a 2-position single solenoid will
result in an unused control signal.
If this is not desired, order with a specified
layout.
*
2 Specified layout: Indicate the wiring
specifications on the manifold specification
sheet. (Note that 2-position double,
3-position, and 4-position valves cannot be
used where single wiring has been
specified.)
*
When the product without the SI unit (S0) is
selected, note the maximum number of
solenoids of the SI unit that will be mounted.
If the layout is specified, indicate it on the
manifold specification sheet.
*
This also includes the number of the blanking
plate assembly.
*
1 16 outputs can be set by switching the built-in
setting switch.
*
2 Ensure a match with the common specification
of the valve.
*
3 ( ): Maximum number of stations for mixed
single and double wiring
*
4 When using the SI unit with 32 outputs, use
the GW unit compatible with the EX500
Gateway Decentralized System 2 (128 points).
*
For mixed mounting, refer to page 165 and
later.
U
Example
q
w
r
e
t y
u
i
q
Series
e
SI unit (Number of outputs, Output polarity,
Max. number of valve stations)
r
Valve stations
*
1 3/5(E) port is plugged for the built-in
silencer type.
*
2 When built-in silencer type is used, keep
the exhaust port from coming into direct
contact with water or other liquids.
y
SUP/EXH block assembly
Nil
Internal pilot
S
Internal pilot, Built-in silencer
*
1
*
2
R
External pilot
t
P, E port entry
U
U side (2 to 10 stations)
D
D side (2 to 10 stations)
B
Both sides (2 to 24 stations)
Stations
Note
02
2 stations
Double wiring
*
1
…
…
16
16 stations
02
2 stations
Specified layout
*
2
(Up to 32 solenoids available)
…
…
24
24 stations
*
1 The SY5000 manifold base is used for the
bottom-ported SY3000. When ordering,
refer to the “Plug-in Mixed Mounting Type
Manifold” (from page 165).
*
When mixing top-ported configurations,
select from those listed on page 110.
In such cases, use caution as there is also
output on the A and B ports on the base side.
Specify on the manifold specification sheet if
plugs are required for the A and B ports on
the base side.
w
Type
10
Side ported
11
Bottom ported
*
1
3
SY3000
5
SY5000
7
SY7000
A3N
0
Without SI unit
A3N
32 outputs
*
1
*
4
, 2 to 16 stations (24
stations
*
3
), Negative common
*
2
97
Type 10
Side Ported
Type 11
Bottom Ported
CAT.ES11-103E 2022-6